Coal Mill Primary Air: Hot and Tempering Air Split

Primary air for a coal mill from the air-to-coal ratio, and the split of hot air-heater air and cold tempering air for the mill inlet temperature.

Thermal power plantProcess steam and utilitiesChemical and fertiliserPulp and paper

Inputs

Examples: 40 t/h coal, A/C 1.8, 320/35 → 250 °CLow load 20 t/h, A/C 2.4, high-moisture coal 290 °C

Results

Constant air specific heat assumed. The required inlet temperature comes from the mill drying balance (see the coal drying calculator) and the outlet temperature limit for the coal's volatile matter.

Primary air flow48.000t/h
Hot air41.492t/h
Tempering air6.5085t/h
Hot air share86.441%
Primary air at 0 °C, 1 atm37,123Nm³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 t/h coal, A/C 1.8, 320/35 → 250 °C. The inputs, in the units selected above:

InputValue
Coal flow to the mill40.000 t/h
Primary air-to-coal ratio1.8000 kg/kg
Hot air temperature (air heater outlet)320.00 °C
Cold (tempering) air temperature35.000 °C
Required mill inlet temperature250.00 °C
Air density at 0 °C, 1 atm1.2930 kg/m³

Applying the formula below gives:

ResultValue
Primary air flow72.000 t/h
Hot air54.316 t/h
Tempering air17.684 t/h
Hot air share75.439 %
Primary air at 0 °C, 1 atm55,684 Nm³/h

Open this example in the calculator and change any input.

Formula

\(\dot m_{PA} = (A/C)\dot m_c, \quad x_h = \frac{T_m - T_c}{T_h - T_c}, \quad \dot m_h = x_h\dot m_{PA}\)

Variables

Symbol Meaning SI unit
\(\dot m_c\) Coal flow to the mill kg/s
\(A/C\) Primary air-to-coal ratio kg/kg
\(T_h\) Hot air temperature (air heater outlet) K
\(T_c\) Cold (tempering) air temperature K
\(T_m\) Required mill inlet temperature K
\(\rho_n\) Air density at 0 °C, 1 atm kg/m³
\(\dot m_{PA}\) Primary air flow kg/s
\(\dot m_h\) Hot air kg/s
\(\dot m_t\) Tempering air kg/s
\(x_h\) Hot air share -
\(\dot V_n\) Primary air at 0 °C, 1 atm Nm³/s

Method and standards

Mixing balance of hot and tempering air with one specific heat for both streams.

Where it is used

  • Mill commissioning and tuning.
  • Checking hot air damper limits.

Common mistakes

  • Using the outlet temperature instead of the inlet.
  • Ignoring seal air entering the mill.

Assumptions and limits

  • Equal specific heats: the specific heat of air rises about 2–3 % from 35 °C to 320 °C, so the hot air share is slightly overstated.
  • The normal density is your input (default 1.293 kg/m³, dry air at 0 °C and 1 atm).

References

  • Mass and heat balance of air mixing (definitions); Babcock & Wilcox
  • Steam: Its Generation and Use
  • 41st ed. (2005)
  • ch. 13 (coal pulverisers)

Questions and answers

What air-to-coal ratio is typical?

1.6–2.2 kg/kg for vertical spindle mills at full load, rising at low load to keep pipe velocities up.

Why temper the air?

Hot air from the air heater is too hot for the mill; cold air is mixed in to reach the inlet temperature the drying balance needs.

What do the defaults give?

40 t/h of coal at 1.8: 72 t/h of primary air, 75 % hot air at 320 °C and 25 % tempering air for a 250 °C mill inlet.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.