FireCADCalc

Bucket Elevator Capacity

Throughput of a bucket elevator from bucket volume, fill factor, bucket spacing, belt or chain speed and the material's bulk density.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationDistillery and ethanolBoiler

Inputs

Examples: Coal elevatorLime elevator

Results

Speed must suit the discharge type (centrifugal or continuous); fill factor depends on the feed arrangement.

Volume throughput27.648m³/h
Mass throughput27.648t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Coal elevator. The inputs, in the units selected above:

InputValue
Bucket volume (water level)4.2000 L
Fill factor75.000 %
Bucket spacing (pitch)0.30000 m
Belt or chain speed1.4000 m/s
Bulk density800.00 kg/m³

Applying the formula below gives:

ResultValue
Volume throughput52.920 m³/h
Mass throughput42.336 t/h

Open this example in the calculator and change any input.

Formula

\(\dot V = \frac{V_b \phi v}{s}, \quad \dot m = \rho_b \dot V\)

Variables

Symbol Meaning SI unit
\(V_b\) Bucket volume (water level) m³
\(\phi\) Fill factor -
\(s\) Bucket spacing (pitch) m
\(v\) Belt or chain speed m/s
\(\rho_b\) Bulk density kg/m³
\(\dot V\) Volume throughput m³/s
\(\dot m\) Mass throughput kg/s

Method and standards

Volumetric throughput from the definition: bucket volume times fill factor, times the number of buckets passing per second (\(v/s\)). The fill factor and speed are your inputs or the maker's figures; no published table is reproduced.

Where it is used

  • Coal, husk and lime handling.

Common mistakes

  • Struck volume used for water-level volume.

Assumptions and limits

  • Steady feed. The speed is not checked against the discharge type (centrifugal or continuous) and the pitch is not checked against the bucket size; take both from the maker.

References

  • Volumetric throughput V̇ = V_b φ v/s

Questions and answers

Fill factor?

Buckets are rarely full: 70–80 % is a common design assumption for free-flowing material; confirm it with the elevator maker.

Speed?

Centrifugal-discharge elevators run faster than continuous-bucket ones.

Sticky or fibrous material?

Bagasse and wet fines need other conveyors.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.