Worked example
Example: 0.136 kg/cm2, water 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Vapour to condense | 11,000 kg/h |
| Condenser pressure (absolute) | 13.337 kPa |
| Injection water temperature | 30.000 °C |
| Approach factor (t_v − t₂)/(t_v − t₁) | 12.000 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Vapour temperature | 51.556 °C |
| Water outlet temperature | 48.969 °C |
| Water per kg vapour, Hugot (607 + 0.3t_v − t₂)/(t₂ − t₁) | 30.233 |
| Water per kg vapour, mean form 572/(t₂ − t₁) | 30.154 |
| Water per kg vapour, IF97 | 30.137 |
| Injection water (IF97) | 331.50 t/h |
| Partial pressure of air at the air outlet (t_a = t₁) | 9.0904 kPa |
Open this example in the calculator and change any input.
Formula
\(t_2 = t_v - k(t_v - t_1), \quad W_H = \frac{607 + 0.3t_v - t_2}{t_2 - t_1}, \quad W = \frac{h_g(t_v) - h_f(t_2)}{h_f(t_2) - h_f(t_1)}, \quad p_a = p - p_{sat}(t_1)\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(Q\) | Vapour to condense | kg/s |
| \(p\) | Condenser pressure (absolute) | Pa |
| \(t_1\) | Injection water temperature | K |
| \(k\) | Approach factor (t_v − t₂)/(t_v − t₁) | - |
| \(t_v\) | Vapour temperature | K |
| \(t_2\) | Water outlet temperature | K |
| \(W_H\) | Water per kg vapour, Hugot (607 + 0.3t_v − t₂)/(t₂ − t₁) | - |
| \(W_m\) | Water per kg vapour, mean form 572/(t₂ − t₁) | - |
| \(W\) | Water per kg vapour, IF97 | - |
| \(\dot m_w\) | Injection water (IF97) | kg/s |
| \(p_a\) | Partial pressure of air at the air outlet (t_a = t₁) | Pa |
Method and standards
Hugot's condenser heat balance with IF97 enthalpies.
Where it is used
- Condenser design.
- Checking injection water pumps.
Common mistakes
- Using vacuum instead of absolute pressure.
- Too small a water rise.
Assumptions and limits
- Counter-current condenser; air leaves at the water inlet temperature.
- The approach factor must be below 1. Notes flag a water rise below 10 °C or an approach below 2 °C (Hugot).
References
- Hugot
- Handbook of Cane Sugar Engineering
- 3rd ed. (Elsevier, 1986)
- ch. 40
- eqns 40.5–40.15
- pp. 860–866
- Water and steam enthalpies from IAPWS-IF97
Questions and answers
Why two water figures?
Hugot's formula uses rounded Regnault enthalpies; IF97 gives the exact heat balance. They differ by a few percent.
What is the approach?
How close the outgoing water comes to the vapour temperature; counter-current condensers approach to about 12 % of the range.
Why does the air pressure matter?
The air pump must handle the air at its own partial pressure; colder air is denser and easier to remove.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.