FireCADCalc

Bagasse Storage Pile Volume and Area

Volume and ground area for storing bagasse loose or baled from the quantity, bulk density and pile height, with a share for access ways.

Sugar mill and cogenerationBoiler

Inputs

Examples: 30 000 t looseBaled

Loose bagasse roughly 100–160 kg/m³; bales much denser.

Results

Large piles heat up and lose value: rotate stock and keep fire lanes.

Pile volume71,429m³
Ground area including access16,667m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 30 000 t loose. The inputs, in the units selected above:

InputValue
Bagasse to store30,000 t
Bulk density (loose or baled)140.00 kg/m³
Average pile height10.000 m
Extra area for access and fire lanes30.000 %

Applying the formula below gives:

ResultValue
Pile volume214,286 m³
Ground area including access27,857 m²

Open this example in the calculator and change any input.

Formula

\(V = \frac{M}{\rho_b}, \quad A = \frac{V}{H}(1 + k_a)\)

Variables

Symbol Meaning SI unit
\(M\) Bagasse to store kg
\(\rho_b\) Bulk density (loose or baled) kg/m³
\(H\) Average pile height m
\(k_a\) Extra area for access and fire lanes -
\(V\) Pile volume m³
\(A\) Ground area including access m²

Method and standards

Definitions.

Where it is used

  • Off-season fuel planning.
  • Yard layout.

Common mistakes

  • Baled density for loose bagasse.

Assumptions and limits

  • Average height; the height is your input (up to 30 m) and is not checked against fire or stability limits.
  • Storage losses (heating, fermentation, decay) are not quantified: allow extra bagasse for them.

References

  • V = M/ρ
  • A = V/H (1 + k); bulk density by measurement

Questions and answers

Loose or baled?

Baling cuts the area several times but costs power and labour.

Does bagasse lose value in storage?

Yes, through fermentation and heating; keep storage time short.

Fire risk?

High: lanes, hydrants and pile height limits matter.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.