Worked example
Example: 50 000 L, hydrometer 815.0 at 27 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Tank volume from the dip at t | 50,000 L |
| Hydrometer reading (density at 20 °C graduation) | 815.00 kg/m³ |
| Temperature of the liquid | 27.000 °C |
| Cubical expansion of the tank steel | 36.000 µm/(m·K) |
| Cubical expansion of the hydrometer glass | 25.000 µm/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| True density at t | 814.86 kg/m³ |
| Strength by mass | 88.833 % |
| Strength by volume at 20 °C | 92.405 % |
| Bulk volume at 20 °C | 49,640 L |
| Absolute alcohol at 20 °C | 45,870 L |
Open this example in the calculator and change any input.
Formula
\(\rho_t = \rho'[1 - \alpha_g(t - 20)], \quad v = V_t\,\frac{p\,\rho_t}{\rho_{20}(1)}[1 + \beta(t - 20)]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_t\) | Tank volume from the dip at t | m³ |
| \(\rho'\) | Hydrometer reading (density at 20 °C graduation) | kg/m³ |
| \(t\) | Temperature of the liquid | K |
| \(\beta\) | Cubical expansion of the tank steel | 1/K |
| \(\alpha_g\) | Cubical expansion of the hydrometer glass | 1/K |
| \(\rho_t\) | True density at t | kg/m³ |
| \(p\) | Strength by mass | - |
| \(q\) | Strength by volume at 20 °C | - |
| \(V_{20}\) | Bulk volume at 20 °C | m³ |
| \(v\) | Absolute alcohol at 20 °C | m³ |
Method and standards
R 22 Annex I (Tables IX and XI) combined.
Where it is used
- Monthly excise stock-taking.
- Receiving tankers.
Common mistakes
- Using the dip volume at t as bulk litres at 20 °C.
- Skipping the hydrometer glass correction.
Assumptions and limits
- Hydrometer glass expansion as entered (soda-lime 25 × 10⁻⁶ /K by default; 0 for a density meter); tank calibrated at 20 °C; well-mixed tank.
References
- OIML R 22 (1973)
- Alcoholometry
- and International Alcoholometric Tables (1975)
- Annex I
- Tables IX and XI
Questions and answers
Why two corrections?
The soda-lime hydrometer (25 × 10⁻⁶ /°C) and the steel tank (36 × 10⁻⁶ /°C) both expand with temperature.
What is LPA?
Litres of pure (absolute) alcohol at 20 °C, the excise quantity.
Can I use a density meter instead?
Yes: enter its true density and set the glass expansion to 0, since a density meter needs no hydrometer correction.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.