Worked example
Example: 10 000 L of 96 % vol at 30 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume measured at t | 10,000 L |
| Strength entered as | % vol (by volume at 20 °C) |
| Alcoholic strength | 96.000 % |
| Temperature of the liquid | 30.000 °C |
| Cubical (volume) expansion of the steel, about 3 × linear | 36.000 µm/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Density at t | 798.72 kg/m³ |
| Bulk volume at 20 °C | 9,895.8 L |
| Pure ethanol at 20 °C | 9,500.0 L |
| Pure ethanol per unit measured volume | 95.000 % |
Open this example in the calculator and change any input.
Formula
\(v = V_t\,\frac{p\,\rho_t}{\rho_{20}(1)}[1 + \beta(t - 20)] = V_t\,\frac{q\,\rho_t}{\rho_{20}}[1 + \beta(t - 20)], \quad V_{20} = V_t\,\frac{\rho_t}{\rho_{20}}[1 + \beta(t - 20)]\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_t\) | Volume measured at t | m³ |
| \(\text{basis}\) | Strength entered as | - |
| \(s\) | Alcoholic strength | - |
| \(t\) | Temperature of the liquid | K |
| \(\beta\) | Cubical (volume) expansion of the steel, about 3 × linear | 1/K |
| \(\rho_t\) | Density at t | kg/m³ |
| \(V_{20}\) | Bulk volume at 20 °C | m³ |
| \(v\) | Pure ethanol at 20 °C | m³ |
| \(v/V_t\) | Pure ethanol per unit measured volume | - |
Method and standards
R 22 Annex I formulas for Tables XI.
Where it is used
- Excise stock-taking.
- Tanker and receiver gauging.
Common mistakes
- Multiplying volume at t by % vol directly.
- Forgetting the tank's own expansion.
Assumptions and limits
- Tank calibrated at 20 °C.
- β is the cubical (volume) coefficient, 36 × 10⁻⁶ /K in R 22; entering the linear coefficient (about 12 × 10⁻⁶) would under-correct the tank by two thirds.
- Uniform temperature.
References
- OIML R 22 (1973)
- Alcoholometry
- and International Alcoholometric Tables (1975)
- Annex I
- Tables XIa and XIb
Questions and answers
Why both a density and a steel term?
The liquid shrinks or swells with temperature, and the tank's calibrated volume grows by β(t − 20).
What is the R 22 formula?
v = p ρt/ρ20(100 %) × [1 + β(t − 20)] per unit measured volume, the same as q ρt/ρ20 × [1 + β(t − 20)].
Is this the same as bulk-litres × % vol?
Only at 20 °C.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.