FireCADCalc

Expected Alcoholometer Reading at t for a True Strength

What a soda-lime glass alcoholometer (% vol) will read at temperature t for a spirit of known true strength at 20 °C: the inverse of OIML R 22 Table VIIIb.

Distillery and ethanol

Inputs

Examples: 40 % vol at 30 °C40 % vol at 10 °C

R 22 formula range −20 to +40 °C.
Enter the cubical (volume) coefficient, about three times the linear one: about 25 × 10⁻⁶ /K for soda-lime glass.

Results

Density at t948.05kg/m³
Density the instrument indicates948.05kg/m³
Expected reading40.000%
Reading minus true strength-5.5511e-15%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 % vol at 30 °C. The inputs, in the units selected above:

InputValue
True strength by volume at 20 °C40.000 %
Temperature of the liquid30.000 °C
Cubical (volume) expansion of the glass, about 3 × linear25.000 µm/(m·K)

Applying the formula below gives:

ResultValue
Density at t941.19 kg/m³
Density the instrument indicates941.43 kg/m³
Expected reading43.939 %
Reading minus true strength3.9386 %

Open this example in the calculator and change any input.

Formula

\(\rho'_{20} = \frac{\rho_t}{1 - a(t - 20)}, \quad r = q(\rho'_{20})\)

Variables

Symbol Meaning SI unit
\(q\) True strength by volume at 20 °C -
\(t\) Temperature of the liquid K
\(a\) Cubical (volume) expansion of the glass, about 3 × linear 1/K
\(\rho_t\) Density at t kg/m³
\(\rho'_{20}\) Density the instrument indicates kg/m³
\(r\) Expected reading -
\(r - q\) Reading minus true strength -

Method and standards

Inverse of the R 22 Table VIII method.

Where it is used

  • Reduction and blending control in the cellar.

Common mistakes

  • Correcting in the wrong direction.
  • Using the % mass scale.

Assumptions and limits

  • % vol alcoholometer graduated at 20 °C.
  • The glass correction uses the first-order form 1/(1 − a(t − 20)); the difference from (1 + a(t − 20)) is negligible over −20 to +40 °C. The surface-tension correction (R 22 Annex II) is not included.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975)
  • Annex I
  • Tables VIIIb (inverted)

Questions and answers

Why would I need the inverse?

To set a target reading for the cellar when reducing spirit at a temperature other than 20 °C.

Is the difference large?

About 0.3–0.4 % vol per °C near 40 % vol.

Which way does it go?

Warmer than 20 °C reads high; colder reads low.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.