Worked example
Example: Reads 42 % vol at 28 °C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Alcoholometer graduated in | % vol |
| Reading of the alcoholometer | 42.000 % |
| Temperature of the liquid | 28.000 °C |
| Cubical (volume) expansion of the glass, about 3 × linear | 25.000 µm/(m·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Density corresponding to the reading | 944.76 kg/m³ |
| True density at t | 944.57 kg/m³ |
| Strength by mass | 32.251 % |
| Strength by volume at 20 °C | 38.817 % |
Open this example in the calculator and change any input.
Formula
\(\rho'_{20} = \rho_{20}(r), \quad \rho_t = \rho'_{20}[1 - a(t - 20)], \quad \rho(p, t) = \rho_t\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\text{scale}\) | Alcoholometer graduated in | - |
| \(r\) | Reading of the alcoholometer | - |
| \(t\) | Temperature of the liquid | K |
| \(a\) | Cubical (volume) expansion of the glass, about 3 × linear | 1/K |
| \(\rho'_{20}\) | Density corresponding to the reading | kg/m³ |
| \(\rho_t\) | True density at t | kg/m³ |
| \(p\) | Strength by mass | - |
| \(q\) | Strength by volume at 20 °C | - |
Method and standards
R 22 Annex I method for Tables VIII.
Where it is used
- Gauging spirits in bonded warehouses.
- Distillery receiver checks.
Common mistakes
- Applying a borosilicate coefficient to a soda-lime instrument.
- Reading the meniscus top instead of the plane of the liquid.
Assumptions and limits
- Instrument graduated at 20 °C.
- No surface-tension correction.
References
- OIML R 22 (1973)
- Alcoholometry
- and International Alcoholometric Tables (1975)
- Annex I
- Tables VIIIa and VIIIb
Questions and answers
Why does a reading at 30 °C overstate the strength?
Warm spirit is less dense, so the alcoholometer sinks deeper and reads high.
Why the glass expansion?
The stem's volume grows with temperature; R 22 corrects with ρt = ρ'20[1 − a(t − 20)], a = 25 × 10⁻⁶ /°C.
Which tables does this replace?
R 22 Tables VIIIa (% mass) and VIIIb (% vol).
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.