Spirit Tank Stock: Absolute Alcohol from Dip and Hydrometer

Litres of absolute alcohol and bulk litres at 20 °C in a steel tank from the dip volume at t, a glass hydrometer density reading and temperature (OIML R 22 IX, XI).

Distillery and ethanolTank and drum

Inputs

Examples: 50 000 L, hydrometer 815.0 at 27 °C20 000 L, hydrometer 948.0 at 15 °CDensity meter (true density 815.0) at 27 °C

R 22 formula range −20 to +40 °C.
Soda-lime glass 25 × 10⁻⁶ /K (R 22); borosilicate is lower, about 10 × 10⁻⁶ /K by the maker. Enter 0 for a density meter, which reads true density.

Results

True density at t815.00kg/m³
Strength by mass91.076%
Strength by volume at 20 °C94.049%
Bulk volume at 20 °C50,000L
Absolute alcohol at 20 °C47,024L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 000 L, hydrometer 815.0 at 27 °C. The inputs, in the units selected above:

InputValue
Tank volume from the dip at t50,000 L
Hydrometer reading (density at 20 °C graduation)815.00 kg/m³
Temperature of the liquid27.000 °C
Cubical expansion of the tank steel36.000 µm/(m·K)
Cubical expansion of the hydrometer glass25.000 µm/(m·K)

Applying the formula below gives:

ResultValue
True density at t814.86 kg/m³
Strength by mass88.833 %
Strength by volume at 20 °C92.405 %
Bulk volume at 20 °C49,640 L
Absolute alcohol at 20 °C45,870 L

Open this example in the calculator and change any input.

Formula

\(\rho_t = \rho'[1 - \alpha_g(t - 20)], \quad v = V_t\,\frac{p\,\rho_t}{\rho_{20}(1)}[1 + \beta(t - 20)]\)

Variables

Symbol Meaning SI unit
\(V_t\) Tank volume from the dip at t m³
\(\rho'\) Hydrometer reading (density at 20 °C graduation) kg/m³
\(t\) Temperature of the liquid K
\(\beta\) Cubical expansion of the tank steel 1/K
\(\alpha_g\) Cubical expansion of the hydrometer glass 1/K
\(\rho_t\) True density at t kg/m³
\(p\) Strength by mass -
\(q\) Strength by volume at 20 °C -
\(V_{20}\) Bulk volume at 20 °C m³
\(v\) Absolute alcohol at 20 °C m³

Method and standards

R 22 Annex I (Tables IX and XI) combined.

Where it is used

  • Monthly excise stock-taking.
  • Receiving tankers.

Common mistakes

  • Using the dip volume at t as bulk litres at 20 °C.
  • Skipping the hydrometer glass correction.

Assumptions and limits

  • Hydrometer glass expansion as entered (soda-lime 25 × 10⁻⁶ /K by default; 0 for a density meter); tank calibrated at 20 °C; well-mixed tank.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975)
  • Annex I
  • Tables IX and XI

Questions and answers

Why two corrections?

The soda-lime hydrometer (25 × 10⁻⁶ /°C) and the steel tank (36 × 10⁻⁶ /°C) both expand with temperature.

What is LPA?

Litres of pure (absolute) alcohol at 20 °C, the excise quantity.

Can I use a density meter instead?

Yes: enter its true density and set the glass expansion to 0, since a density meter needs no hydrometer correction.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.