FireCADCalc

Reduction Water to Bring Spirit to Bottling Strength (OIML)

Water to add to a spirit of known % vol to reach a bottling strength, and the final volume at 20 °C, by mass balance with OIML R 22 densities (contraction included).

Distillery and ethanol

Inputs

Examples: 1 000 L of 96 % to 40 %Cask 63.5 % to 46 %

Results

Add the water slowly with mixing and check the strength after the blend has returned to 20 °C.

Water to add78.664kg
Water to add at 20 °C78.806L
Final volume at 20 °C276.09L
Water by the naive volume rule76.087L

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1 000 L of 96 % to 40 %. The inputs, in the units selected above:

InputValue
Spirit volume at 20 °C1,000.0 L
Spirit strength96.000 %
Bottling strength40.000 %

Applying the formula below gives:

ResultValue
Water to add1,467.9 kg
Water to add at 20 °C1,470.5 L
Final volume at 20 °C2,400.0 L
Water by the naive volume rule1,400.0 L

Open this example in the calculator and change any input.

Formula

\(p_2 m_2 = p_1 m_1, \quad m_w = m_2 - m_1, \quad V_2 = \frac{m_2}{\rho_{20}(p_2)}\)

Variables

Symbol Meaning SI unit
\(V_1\) Spirit volume at 20 °C m³
\(q_1\) Spirit strength -
\(q_2\) Bottling strength -
\(m_w\) Water to add kg
\(V_w\) Water to add at 20 °C m³
\(V_2\) Final volume at 20 °C m³
\(V_1(q_1/q_2 - 1)\) Water by the naive volume rule m³

Method and standards

Mass balance with R 22 densities.

Where it is used

  • Bottling hall reduction.
  • Blending vodka, whisky, rum and gin.

Common mistakes

  • Using the naive volume rule.
  • Ignoring temperature.

Assumptions and limits

  • Volumes at 20 °C; pure water.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975): formula of Wagenbreth and Blanke
  • pp. 12–13

Questions and answers

Why is the naive rule wrong?

It ignores contraction: more water is needed than V1(q1/q2 − 1) to reach the strength.

What water should be used?

Demineralised water, to avoid haze.

Why measure again at 20 °C?

Mixing releases heat, and strength by volume is defined at 20 °C.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.