Hydrometer or Glass Density Meter for Alcohol → Strength

True density and alcoholic strength from a hydrometer for alcohol (soda-lime glass) or a borosilicate density meter read at t, OIML R 22 Tables IX and X.

Distillery and ethanol

Inputs

Examples: Soda-lime hydrometer 951.0 at 25 °CBorosilicate meter 870.0 at 12 °C

R 22 formula range −20 to +40 °C.

Results

Cubical expansion used10.000µm/(m·K)
True density at t870.07kg/m³
Strength by mass71.795%
Strength by volume at 20 °C78.534%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Soda-lime hydrometer 951.0 at 25 °C. The inputs, in the units selected above:

InputValue
Reading (density graduated at 20 °C)951.00 kg/m³
Temperature of the liquid25.000 °C
Instrument glassSoda-lime glass (25 × 10⁻⁶ /°C)

Applying the formula below gives:

ResultValue
Cubical expansion used25.000 µm/(m·K)
True density at t950.88 kg/m³
Strength by mass29.859 %
Strength by volume at 20 °C36.093 %

Open this example in the calculator and change any input.

Formula

\(\rho_t = \rho'[1 - a(t - 20)], \quad \rho(p, t) = \rho_t\)

Variables

Symbol Meaning SI unit
\(\rho'\) Reading (density graduated at 20 °C) kg/m³
\(t\) Temperature of the liquid K
\(\text{glass}\) Instrument glass -
\(a\) Cubical expansion used 1/K
\(\rho_t\) True density at t kg/m³
\(p\) Strength by mass -
\(q\) Strength by volume at 20 °C -

Method and standards

R 22 Annex I method for Tables IX and X.

Where it is used

  • Bonded warehouse gauging.
  • Quality control of spirits.

Common mistakes

  • Using the reading directly as the density at t.
  • Wrong glass coefficient.

Assumptions and limits

  • Graduated at 20 °C; no surface-tension correction.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975)
  • Annex I
  • Tables IXa
  • IXb
  • Xa and Xb

Questions and answers

What is a hydrometer for alcohol?

A glass hydrometer graduated in density at 20 °C rather than in strength.

Why two glasses?

R 22 uses 25 × 10⁻⁶ /°C for soda-lime glass and 10 × 10⁻⁶ /°C for borosilicate.

Does an electronic meter need this?

No, oscillating-tube meters compensate internally.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.