FireCADCalc

Ethanol–Water Density by OIML R 22 (−20 to +40 °C)

Density of an ethanol–water mixture from its alcoholic strength by mass or volume and temperature by the OIML R 22 formula, as in Tables I and II.

Distillery and ethanolTank and drum

Inputs

Examples: 40 % vol at 30 °C50 % mass at −10 °C (Table I: 936.56)

R 22 formula range −20 to +40 °C.

Results

Below 0 °C weak mixtures freeze: R 22 Table I starts at the strength that just stays liquid at each temperature. The formula still returns a number for a frozen mixture, so check that yours is liquid.

Strength by mass50.000%
Strength by volume at 20 °C57.889%
Density at the temperature t936.56kg/m³
Density at 20 °C913.77kg/m³

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 % vol at 30 °C. The inputs, in the units selected above:

InputValue
Strength entered as% vol (by volume at 20 °C)
Alcoholic strength40.000 %
Temperature of the liquid30.000 °C

Applying the formula below gives:

ResultValue
Strength by mass33.300 %
Strength by volume at 20 °C40.000 %
Density at the temperature t941.19 kg/m³
Density at 20 °C948.05 kg/m³

Open this example in the calculator and change any input.

Formula

\(\rho = A_1 + \sum_{k=2}^{12} A_k p^{k-1} + \sum_{k=1}^{6} B_k (t - 20)^k + \sum_{i=1}^{5}\sum_{k=1}^{m_i} C_{i,k}\, p^k (t - 20)^i\)

\(q = p\,\frac{\rho_{20}(p)}{\rho_{20}(1)}, \quad \rho_{20}(1) \approx 789.24\ \mathrm{kg/m^3}\)

Variables

Symbol Meaning SI unit
\(\text{basis}\) Strength entered as -
\(s\) Alcoholic strength -
\(t\) Temperature of the liquid K
\(p\) Strength by mass -
\(q\) Strength by volume at 20 °C -
\(\rho_t\) Density at the temperature t kg/m³
\(\rho_{20}\) Density at 20 °C kg/m³
\(A_k, B_k, C_{i,k}\) Coefficients of the R 22 formula (p. 13) -

Method and standards

The OIML R 22 (Wagenbreth–Blanke) polynomial with the published coefficients; strength by volume by the R 22 definition (introduction §4).

Where it is used

  • Excise and customs gauging of spirits.
  • Converting meter densities in distilleries and bottling halls.

Common mistakes

  • Entering % vol where % mass is expected.
  • Using the formula outside −20 to +40 °C.

Assumptions and limits

  • Pure ethanol–water mixtures; other congeners shift the density slightly.
  • Below 0 °C weak mixtures freeze. No freezing check is made: the formula returns a density for a mixture that would be frozen, and a note reminds you below 0 °C.
  • Temperature on IPTS-68; the difference from ITS-90 is far below the table resolution.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975): formula of Wagenbreth and Blanke
  • pp. 12–13

Questions and answers

Why does the density depend on strength by mass?

R 22 writes its formula in strength by mass p; strength by volume is converted through q = p ρ20(p)/ρ20(1).

How exact is the formula?

It reproduces the printed tables to 0.01 kg/m³; the tables themselves are generated from it.

Can I use it above 40 °C?

No. The formula is fitted from −20 °C to +40 °C only.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.