Alcoholometer Surface-Tension Correction (OIML R 22 Annex II)

Correction K to add to an alcoholometer or hydrometer reading when the liquid's surface tension differs from that at 20 °C, by OIML R 22 Annex II.

Distillery and ethanol

Inputs

Examples: 40 % mass at 0 °C: 31.3 vs 29.9 mN/mStrong spirit at 40 °C: 20.7 vs 22.4 mN/mDensity hydrometer reading 95.0 (kg/m³ ÷ 10), 40 % mass at 0 °C

R 22 Annex II table, e.g. 40 % mass: 31.3 mN/m at 0 °C, 29.9 at 20 °C.

Results

Correction to add (scale units)0.087773
Corrected reading96.088

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 40 % mass at 0 °C: 31.3 vs 29.9 mN/m. The inputs, in the units selected above:

InputValue
Reading (scale units, e.g. % vol)42.000 -
Surface tension of the liquid at t31.300 mN/m
Surface tension at 20 °C (instrument adjustment)29.900 mN/m
Sensitivity: scale length per scale unit3.0000 mm
Stem diameter4.0000 mm
Density of the liquid950.00 kg/m³
Scale of the instrumentAlcoholometer: strength (% vol or % mass) rises up the stem

Applying the formula below gives:

ResultValue
Correction to add (scale units)-0.050091
Corrected reading41.950

Open this example in the calculator and change any input.

Formula

\(K = s\,\frac{4}{g E d \rho}\,[\gamma - \gamma(20\,°C)], \quad s = -1 \text{ (alcoholometer)}, \; +1 \text{ (density hydrometer)}\)

Variables

Symbol Meaning SI unit
\(r\) Reading (scale units, e.g. % vol) -
\(\gamma\) Surface tension of the liquid at t N/m
\(\gamma(20\,°C)\) Surface tension at 20 °C (instrument adjustment) N/m
\(E\) Sensitivity: scale length per scale unit m
\(d\) Stem diameter m
\(\rho\) Density of the liquid kg/m³
\(K\) Correction to add (scale units) -
\(r + K\) Corrected reading -
\(s\) Scale direction: −1 for an alcoholometer (strength rises up the stem), +1 for a density hydrometer -
\(g\) Standard acceleration of gravity, 9.806 65 m/s²

Method and standards

OIML R 22 (1975), Annex II, p. 8: add the correction K = 4[γ − γ(20 °C)]/(g E d ρ) to the reading, with g = 9.806 65 m/s². R 22 does not state the sign for each kind of scale; it follows from the physics. A higher surface tension pulls the instrument deeper by 4Δγ/(ρ g d). On a density hydrometer, where values rise down the stem, it then reads low and K is added as printed. On an alcoholometer, where strength rises up the stem, it reads high and the correction changes sign.

Where it is used

  • Precise gauging of spirits at low or high temperature.

Common mistakes

  • Using E in scale units per mm (the inverse).
  • Forgetting to add K to the reading.
  • Using the density-hydrometer sign on an alcoholometer: the correction is then twice as wrong as none.

Assumptions and limits

  • Clean stem, standard meniscus.
  • The density entered must be that of the liquid at the reading; it is not checked against the reading.

References

  • OIML R 22 (1973)
  • Alcoholometry
  • and International Alcoholometric Tables (1975)
  • Annex II
  • correction of surface tension

Questions and answers

Why does surface tension change the reading?

The meniscus pulls the stem down with a force of γπd; a different γ moves the float.

Where do γ values come from?

R 22 Annex II tabulates γ against strength by mass and temperature, from 20.7 to 75.6 mN/m.

Is the correction large?

Usually a few hundredths of a scale unit; it matters for precise gauging far from 20 °C.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.