Worked example
Example: 40 % mass at 0 °C: 31.3 vs 29.9 mN/m. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Reading (scale units, e.g. % vol) | 42.000 - |
| Surface tension of the liquid at t | 31.300 mN/m |
| Surface tension at 20 °C (instrument adjustment) | 29.900 mN/m |
| Sensitivity: scale length per scale unit | 3.0000 mm |
| Stem diameter | 4.0000 mm |
| Density of the liquid | 950.00 kg/m³ |
| Scale of the instrument | Alcoholometer: strength (% vol or % mass) rises up the stem |
Applying the formula below gives:
| Result | Value |
|---|---|
| Correction to add (scale units) | -0.050091 |
| Corrected reading | 41.950 |
Open this example in the calculator and change any input.
Formula
\(K = s\,\frac{4}{g E d \rho}\,[\gamma - \gamma(20\,°C)], \quad s = -1 \text{ (alcoholometer)}, \; +1 \text{ (density hydrometer)}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(r\) | Reading (scale units, e.g. % vol) | - |
| \(\gamma\) | Surface tension of the liquid at t | N/m |
| \(\gamma(20\,°C)\) | Surface tension at 20 °C (instrument adjustment) | N/m |
| \(E\) | Sensitivity: scale length per scale unit | m |
| \(d\) | Stem diameter | m |
| \(\rho\) | Density of the liquid | kg/m³ |
| \(K\) | Correction to add (scale units) | - |
| \(r + K\) | Corrected reading | - |
| \(s\) | Scale direction: −1 for an alcoholometer (strength rises up the stem), +1 for a density hydrometer | - |
| \(g\) | Standard acceleration of gravity, 9.806 65 | m/s² |
Method and standards
OIML R 22 (1975), Annex II, p. 8: add the correction K = 4[γ − γ(20 °C)]/(g E d ρ) to the reading, with g = 9.806 65 m/s². R 22 does not state the sign for each kind of scale; it follows from the physics. A higher surface tension pulls the instrument deeper by 4Δγ/(ρ g d). On a density hydrometer, where values rise down the stem, it then reads low and K is added as printed. On an alcoholometer, where strength rises up the stem, it reads high and the correction changes sign.
Where it is used
- Precise gauging of spirits at low or high temperature.
Common mistakes
- Using E in scale units per mm (the inverse).
- Forgetting to add K to the reading.
- Using the density-hydrometer sign on an alcoholometer: the correction is then twice as wrong as none.
Assumptions and limits
- Clean stem, standard meniscus.
- The density entered must be that of the liquid at the reading; it is not checked against the reading.
References
- OIML R 22 (1973)
- Alcoholometry
- and International Alcoholometric Tables (1975)
- Annex II
- correction of surface tension
Questions and answers
Why does surface tension change the reading?
The meniscus pulls the stem down with a force of γπd; a different γ moves the float.
Where do γ values come from?
R 22 Annex II tabulates γ against strength by mass and temperature, from 20.7 to 75.6 mN/m.
Is the correction large?
Usually a few hundredths of a scale unit; it matters for precise gauging far from 20 °C.