FireCADCalc

Power to Lift or Hoist a Load

Power to raise a load at a speed through a mechanism efficiency, the motor power, the energy per lift and the potential energy gained.

Inputs

Examples: 2 t at 15 m/min, 10 m, 80 %500 kg at 30 m/min, 6 m, 85 %10 t at 5 m/min, 20 m, 75 %

Results

Steady lifting; acceleration needs extra torque for a short time.

Power at the load m g v8.1722kW
Motor power P_l/η10.896kW
Potential energy gained m g H1,961.3kJ
Time for the lift240.00s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 2 t at 15 m/min, 10 m, 80 %. The inputs, in the units selected above:

InputValue
Mass lifted (load plus hook and cage)2,000.0 kg
Lifting speed15.000 m/min
Height of the lift10.000 m
Efficiency of the gearing, ropes and drum80.000 %

Applying the formula below gives:

ResultValue
Power at the load m g v4.9033 kW
Motor power P_l/η6.1292 kW
Potential energy gained m g H196.13 kJ
Time for the lift40.000 s

Open this example in the calculator and change any input.

Formula

\(P_l = m g v, \quad P_m = \frac{P_l}{\eta}, \quad E_p = m g H\)

Variables

Symbol Meaning SI unit
\(m\) Mass lifted (load plus hook and cage) kg
\(v\) Lifting speed m/s
\(H\) Height of the lift m
\(\eta\) Efficiency of the gearing, ropes and drum -
\(P_l\) Power at the load m g v W
\(P_m\) Motor power P_l/η W
\(E_p\) Potential energy gained m g H J
\(t\) Time for the lift s

Method and standards

Work and power.

Where it is used

  • Hoists, lifts and winches.
  • Mechanics examinations.

Common mistakes

  • Forgetting the hook and rope mass.
  • Ignoring efficiency.

Assumptions and limits

  • Constant speed. The motor power has no allowance for acceleration torque, motor efficiency or a duty/service factor: add them for motor selection.

References

  • Textbook mechanics (power = force × velocity)

Questions and answers

2 t at 15 m/min through 80 % efficiency?

4.9 kW at the load, 6.1 kW at the motor.

How long for 10 m?

40 s.

What about acceleration?

Add m a v for the starting period; motors have a short-time overload rating.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.