FireCADCalc

Damping from Free Vibration: Logarithmic Decrement

Logarithmic decrement, damping ratio, damped natural frequency and quality factor from two peak amplitudes a number of cycles apart in a free-vibration decay.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 → 4 mm over 5 cycles at 12 HzLightly damped steel 1.0 → 0.8 over 10

Results

Viscous damping assumed; friction damping gives a linear, not exponential, decay. A bump test of a structure gives this decay directly.

Logarithmic decrement0.18326
Damping ratio2.9154%
Undamped natural frequency12.005Hz
Quality factor 1/(2ζ)17.150

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 → 4 mm over 5 cycles at 12 Hz. The inputs, in the units selected above:

InputValue
First peak amplitude10.000 mm
Peak amplitude n cycles later4.0000 mm
Cycles between the peaks5.0000 -
Measured damped frequency12.000 Hz

Applying the formula below gives:

ResultValue
Logarithmic decrement0.18326
Damping ratio2.9154 %
Undamped natural frequency12.005 Hz
Quality factor 1/(2ζ)17.150

Open this example in the calculator and change any input.

Formula

\(\delta = \frac1n\ln\frac{x_1}{x_{n+1}}, \quad \zeta = \frac{\delta}{\sqrt{4\pi^2 + \delta^2}}, \quad f_n = \frac{f_d}{\sqrt{1 - \zeta^2}}\)

Variables

Symbol Meaning SI unit
\(x_1\) First peak amplitude m
\(x_{n+1}\) Peak amplitude n cycles later m
\(n\) Cycles between the peaks -
\(f_d\) Measured damped frequency 1/s
\(\delta\) Logarithmic decrement -
\(\zeta\) Damping ratio -
\(f_n\) Undamped natural frequency 1/s
\(Q\) Quality factor 1/(2ζ) -

Method and standards

Viscous damping decay.

Where it is used

  • Bump tests of foundations and pipework.
  • Checking mount damping.

Common mistakes

  • Using peaks of opposite sign.
  • Mixing displacement and acceleration peaks over changing frequency.

Assumptions and limits

  • Viscous damping; single mode.

References

  • Rao
  • Mechanical Vibrations
  • 6th ed. (Pearson, 2017)
  • ch. 2 (logarithmic decrement)

Questions and answers

Why measure over several cycles?

Lightly damped systems lose little per cycle; measuring over n cycles improves accuracy.

What damping is typical?

Steel structures 1–2 %, bolted structures 2–5 %, rubber mounts 5–10 %.

What do the defaults represent?

A decay from 10 to 4 mm over 5 cycles at 12 Hz.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.