FireCADCalc

Banked Curve: Safe Speed and Required Banking Angle

Speed for no side friction on a banked curve, the maximum speed before skidding with side friction, and the banking angle or rail superelevation for a design speed.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 300 m, 4°, μ 0.15, 80 km/h, broad gaugePlant road 60 m, 3°, μ 0.3, 30 km/h, standard gauge

Results

Point-mass model without overturning; road and rail design use codes with comfort limits on unbalanced lateral acceleration.

Speed for no side friction19.991km/h
Maximum speed before skidding52.252km/h
Banking for the design speed (no friction)6.7311°
Rail superelevation for the design speed169.36mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 300 m, 4°, μ 0.15, 80 km/h, broad gauge. The inputs, in the units selected above:

InputValue
Curve radius300.00 m
Banking angle4.0000 °
Side friction coefficient0.15000 -
Design speed (for required banking)80.000 km/h
Rail gauge (for superelevation)1.6760 m

Applying the formula below gives:

ResultValue
Speed for no side friction51.635 km/h
Maximum speed before skidding92.056 km/h
Banking for the design speed (no friction)9.5285 °
Rail superelevation for the design speed281.32 mm

Open this example in the calculator and change any input.

Formula

\(v_0 = \sqrt{gR\tan\theta}, \quad v_{max} = \sqrt{gR\frac{\tan\theta + \mu}{1 - \mu\tan\theta}}, \quad \tan\theta_{req} = \frac{v^2}{gR}, \quad e = \frac{Gv^2}{gR}\)

Variables

Symbol Meaning SI unit
\(R\) Curve radius m
\(\theta\) Banking angle rad
\(\mu\) Side friction coefficient -
\(v\) Design speed (for required banking) m/s
\(G\) Rail gauge (for superelevation) m
\(v_0\) Speed for no side friction m/s
\(v_{max}\) Maximum speed before skidding m/s
\(\theta_{req}\) Banking for the design speed (no friction) rad
\(e\) Rail superelevation for the design speed m

Method and standards

Curvilinear dynamics.

Where it is used

  • Plant roads and rail sidings.
  • Teaching.

Common mistakes

  • Using design-code friction values as physical friction.
  • Ignoring rollover for high vehicles.

Assumptions and limits

  • Point mass; steady speed.
  • Rail superelevation e = Gv²/(gR) is the small-angle form (G tan θ in place of G sin θ); the difference is under 0.5 % for usual cant, larger for steep angles. Whether the required angle is practicable (cant limits) is not checked.

References

  • Meriam and Kraige
  • Engineering Mechanics: Dynamics
  • 8th ed. (Wiley, 2015)
  • ch. 3 (curvilinear motion with friction)

Questions and answers

Why bank a curve?

A tilted surface supplies part of the centripetal force, reducing the side friction needed.

What is superelevation on rail?

The height of the outer rail above the inner; e = Gv²/(gR) balances a given speed.

What do the defaults represent?

A 300 m curve banked at 4° with side friction 0.15; 80 km/h design speed on broad-gauge track.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.