Worked example
Example: Ganapathy: triplex, 3 in line 8 ft. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Suction line length | 2.4384 m |
| Average flow | 8.1765 m³/h |
| Suction line inner diameter | 77.927 mm |
| Pump speed | 360.00 rpm |
| Pump type | Triplex (0.066) |
| Liquid factor | Deaerated water (1.4) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Mean velocity in the suction line | 0.47621 m/s |
| Acceleration head | 2.0096 m |
Open this example in the calculator and change any input.
Formula
\(H_a = \frac{L\,V\,N\,C}{K\,g}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(L\) | Suction line length | m |
| \(Q\) | Average flow | m³/s |
| \(d\) | Suction line inner diameter | m |
| \(N\) | Pump speed | 1/s |
| \(C\) | Pump type | - |
| \(K\) | Liquid factor | - |
| \(V\) | Mean velocity in the suction line | m/s |
| \(H_a\) | Acceleration head | m |
Method and standards
Ganapathy's Q5.17 (N in rpm; any consistent length units).
Where it is used
- Boiler chemical dosing and high-pressure pumps.
- Reciprocating feed pumps.
Common mistakes
- Using the developed length.
- Forgetting each line segment separately.
Assumptions and limits
- Rigid suction line; sum segments of different size.
References
- Ganapathy
- Steam Plant Calculations Manual
- 2nd ed. (Marcel Dekker, 1993)
- Q5.17 (acceleration head; constants C and K)
Questions and answers
Why an acceleration head?
The liquid column in the suction line must be accelerated on every stroke; without enough head it separates and the pump knocks.
What do C and K mean?
C reflects the flow pulsation of the pump type; K the liquid's compressibility.
What does Ganapathy's example give?
A triplex at 360 rpm, 36 gpm, with 8 ft of 3 in line (3.068 in bore) gives 6.6 ft (2.01 m); the 18 ft of 2 in line (2.067 in bore) adds 32.7 ft (9.96 m). The book prints 6.7 ft and 32.9 ft; the small difference is rounding in its working.
Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.