FireCADCalc

Pump and System Curve Operating Point

Flow and head where a pump curve H = H₀ − a Q² meets a system curve H = H_s + b Q², with the power at that point, from two points of each curve.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserHydraulic Institute (pumps)

Inputs

Examples: 50 m shut-off, 40 m at 100 m³/h; 15 m static, 30 m at 100 m³/hBoiler feed: 160 m, 140 m at 30 m³/h; 110 m static, 130 m at 30 m³/hCirculation (no static): 20 m, 16 m at 200 m³/h; 12 m at 200 m³/h

Results

Both curves approximated by parabolas through the points given; check against the maker's full curve.

Flow at the operating point33.541m³/h
Head at the operating point135.00m
Shaft power at the operating point18.028kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 m shut-off, 40 m at 100 m³/h; 15 m static, 30 m at 100 m³/h. The inputs, in the units selected above:

InputValue
Pump shut-off head50.000 m
A pump flow on its curve100.00 m³/h
Pump head at that flow40.000 m
Static head of the system15.000 m
A system flow100.00 m³/h
System head at that flow (static + friction)30.000 m
Pump efficiency at the duty75.000 %
Liquid density998.00 kg/m³

Applying the formula below gives:

ResultValue
Flow at the operating point118.32 m³/h
Head at the operating point36.000 m
Shaft power at the operating point15.440 kW

Open this example in the calculator and change any input.

Formula

\(H_{pump} = H_0 - aQ^2, \quad H_{sys} = H_s + bQ^2, \quad Q^* = \sqrt{\frac{H_0 - H_s}{a + b}}\)

Variables

Symbol Meaning SI unit
\(H_0\) Pump shut-off head m
\(Q_r\) A pump flow on its curve m³/s
\(H_r\) Pump head at that flow m
\(H_s\) Static head of the system m
\(Q_s\) A system flow m³/s
\(H_{s,Q}\) System head at that flow (static + friction) m
\(\eta\) Pump efficiency at the duty -
\(\rho\) Liquid density kg/m³
\(Q\) Flow at the operating point m³/s
\(H\) Head at the operating point m
\(P\) Shaft power at the operating point W

Method and standards

Intersection of two parabolas.

Where it is used

  • Pump selection and troubleshooting.
  • Energy studies.

Common mistakes

  • Ignoring static head.
  • Extrapolating the pump curve.

Assumptions and limits

  • Parabolic curve shapes.
  • The pump efficiency is a fixed input, not read at the computed operating point: take it from the maker's curve at the flow found and repeat if it differs.

References

  • Parabolic pump and system curves (Textbook fluid mechanics (White, Fluid Mechanics); Hydraulic Institute)

Questions and answers

50 m shut-off, 40 m at 100 m³/h; system 15 m static, 30 m at 100 m³/h?

Operating point about 118 m³/h at 36.0 m.

Why not exactly the design point?

Pumps run where the curves cross, not where the datasheet says.

How to move the point?

Throttle (raise the system curve), trim the impeller or change speed.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.