Pump Affinity Laws (Speed and Impeller Trim)

New flow, head and power of a centrifugal pump when the speed changes or the impeller is trimmed, by the affinity laws.

Thermal power plantProcess steam and utilitiesRefinery and petrochemicalChemical and fertiliserHydraulic Institute (pumps)Pump

Inputs

Examples: Speed 2 950 to 2 400 rpm (VFD)Impeller trim 320 to 290 mm at 1 480 rpm60 Hz pump on 50 Hz: 3 550 to 2 950 rpm

Known duty

New duty

Results

New flow271.87m³/h
New head45.171m
New shaft power44.658kW
Combined ratio N₂D₂ / N₁D₁0.90625

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Speed 2 950 to 2 400 rpm (VFD). The inputs, in the units selected above:

InputValue
Flow100.00 m³/h
Head80.000 m
Shaft power30.000 kW
Speed2,950.0 rpm
Impeller diameter250.00 mm
New speed2,400.0 rpm
New impeller diameter (same as above = no trim)250.00 mm

Applying the formula below gives:

ResultValue
New flow81.356 m³/h
New head52.950 m
New shaft power16.154 kW
Combined ratio N₂D₂ / N₁D₁0.81356

Open this example in the calculator and change any input.

Formula

\(k = \frac{N_2\,D_2}{N_1\,D_1} \qquad Q_2 = k\,Q_1 \qquad H_2 = k^2\,H_1 \qquad P_2 = k^3\,P_1\)

Variables

Symbol Meaning SI unit
\(Q_1\) known flow m³/s
\(H_1\) known head m
\(P_1\) known shaft power W
\(N_1\) known speed 1/s
\(D_1\) known impeller diameter m
\(N_2\) new speed 1/s
\(D_2\) new impeller diameter m
\(Q_2\) new flow m³/s
\(H_2\) new head m
\(P_2\) new shaft power W
\(k\) combined ratio of speed and diameter –

Method and standards

The affinity rules as given in ANSI/HI 1.3 for a centrifugal pump: corresponding points on the curves at two speeds, or with a trimmed impeller in the same casing, have the same efficiency and scale with the ratio of speed times diameter.

Where it is used

  • Predicting flow, head and power after a speed change or VFD.
  • Impeller trimming estimates.
  • Energy-saving studies of throttled pumps.

Common mistakes

  • Applying the laws to a system with large static head: the operating point does not scale.
  • Using them for large impeller trims beyond about 10 %.
  • Forgetting that efficiency changes off the best efficiency point.

Assumptions and limits

  • Corresponding points only: the result is a point on the new pump curve, not the new operating point; that is where the new curve meets the system curve.
  • Efficiency unchanged; valid for moderate speed changes and trims up to about 20 %. No efficiency scaling (such as Moody's) is applied, and no warning is given for large speed changes: below about half speed the efficiency falls and the power is higher than k³ P₁.
  • Same liquid; NPSH required scales roughly with speed squared and must be checked separately.

References

  • ANSI/HI 1.3 (centrifugal pump application, affinity rules)

Questions and answers

What are the pump affinity laws?

Flow varies with speed, head with speed squared and power with speed cubed. Slowing a pump from 2 950 to 2 400 rpm gives 81 % of the flow, 66 % of the head and 54 % of the power.

Do the same laws apply to trimming the impeller?

Approximately, with the diameter ratio in place of the speed ratio, for trims up to about 10–20 %. Trimming also changes the impeller geometry, so real pumps lose slightly more head; makers apply a correction.

Will a VFD always save the cube of the speed?

Only when the system is all friction. A boiler feed pump works against a high static pressure, so its operating point does not follow the affinity parabola and the saving is much smaller.

Method and article reviewed by FireCAD engineering on 10 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.