FireCADCalc

Hydraulic Line Sizing: Velocity and Pressure Drop

Inside diameter of a hydraulic pressure, return or suction line from flow and recommended velocity, and the pressure drop in the chosen line.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 60 L/min VG32 in 19 mm pressure lineSuction 120 L/min, 50 mm

Results

Velocities are common practice (pressure lines 2–6 m/s, returns 2–4, suctions 0.6–1.5). Viscosity rises steeply when cold: check start-up pressure drop on suction lines.

Minimum diameter for the velocity46.066mm
Velocity in the chosen line1.0186m/s
Reynolds number1,107.2
Pressure drop0.010496bar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 60 L/min VG32 in 19 mm pressure line. The inputs, in the units selected above:

InputValue
Flow60.000 L/min
Line typePressure line (4.5 m/s)
Chosen inside diameter19.000 mm
Line length (equivalent)10.000 m
Oil kinematic viscosity32.000 cSt
Oil density870.00 kg/m³

Applying the formula below gives:

ResultValue
Minimum diameter for the velocity16.821 mm
Velocity in the chosen line3.5270 m/s
Reynolds number2,094.1
Pressure drop0.87039 bar

Open this example in the calculator and change any input.

Formula

\(d_{min} = \sqrt{\frac{4Q}{\pi v_{max}}}, \quad \Delta p = f_D\frac{L}{d}\frac{\rho v^2}{2}\)

Variables

Symbol Meaning SI unit
\(Q\) Flow m³/s
\(\text{line}\) Line type -
\(d\) Chosen inside diameter m
\(L\) Line length (equivalent) m
\(\nu\) Oil kinematic viscosity m²/s
\(\rho\) Oil density kg/m³
\(d_{min}\) Minimum diameter for the velocity m
\(v\) Velocity in the chosen line m/s
\(Re\) Reynolds number -
\(\Delta p\) Pressure drop Pa

Method and standards

Pipe friction.

Where it is used

  • Hydraulic power unit layout.
  • Checking hose sizes.

Common mistakes

  • Using nominal hose size as inside diameter.
  • Warm-oil viscosity for cold starts.

Assumptions and limits

  • Drawn tube, roughness 1.5 µm; isothermal; laminar f = 64/Re below Re 2 300.
  • A velocity above the line type's figure is flagged.

References

  • Darcy–Weisbach with laminar and Colebrook friction (FireCAD engine); recommended velocities from fluid power practice

Questions and answers

Why lower velocity in suction lines?

To keep the pump inlet above vapour pressure and avoid cavitation.

Is hydraulic flow usually laminar?

In small lines with warm oil, often yes; below Re 2,300 the calculator uses f = 64/Re.

What do the defaults represent?

60 L/min of ISO VG 32 oil in a 19 mm pressure line, 10 m long.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.