FireCADCalc

Hydraulic Cylinder Rod Buckling (Euler, by Mounting)

Euler buckling load of a hydraulic cylinder piston rod from diameter, extended length, mounting and modulus, with the safety factor at working force.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 50 mm rod, 1.5 m, fixed–free, 80 kN70 mm rod, 2 m, pinned–pinned, 150 kNShort rod: 60 mm, 0.6 m, pinned–pinned, yield 400 MPa (Johnson)

With a yield strength, short rods (KL/r below the transition) use the Johnson parabola instead of Euler.

Results

Rod only, as commonly used for quick checks; the cylinder tube adds stiffness. Use a safety factor of at least 3–4.

Second moment of area1,178,588mm⁴
Buckling load (Euler; Johnson for a short rod when σ_y is given)601.97kN
Safety factor4.0131
Slenderness ratio114.29

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 50 mm rod, 1.5 m, fixed–free, 80 kN. The inputs, in the units selected above:

InputValue
Rod diameter50.000 mm
Fully extended length (mounting to load)1.5000 m
Effective length factorFixed–free (2.0)
Elastic modulus207.00 GPa
Rod yield strength (0 = Euler only)0 MPa
Working force80.000 kN

Applying the formula below gives:

ResultValue
Second moment of area306,796 mm⁴
Buckling load (Euler; Johnson for a short rod when σ_y is given)69.643 kN
Safety factor0.87054
Slenderness ratio240.00

Open this example in the calculator and change any input.

Formula

\(P_{cr} = \frac{\pi^2EI}{(KL)^2}, \quad I = \frac{\pi d^4}{64}, \quad SF = \frac{P_{cr}}{F}\) \(P_{cr} = A\sigma_y\left[1 - \frac{\sigma_y}{4\pi^2E}\left(\frac{KL}{r}\right)^2\right]\ \ \text{(Johnson, when}\ \frac{KL}{r} < \sqrt{\frac{2\pi^2E}{\sigma_y}}\text{)}, \quad A = \frac{\pi d^2}{4}, \quad r = \frac d4\)

Variables

Symbol Meaning SI unit
\(d\) Rod diameter m
\(L\) Fully extended length (mounting to load) m
\(K\) Effective length factor -
\(E\) Elastic modulus Pa
\(\sigma_y\) Rod yield strength (0 = Euler only) Pa
\(F\) Working force N
\(I\) Second moment of area m⁴
\(P_{cr}\) Buckling load (Euler; Johnson for a short rod when σ_y is given) N
\(SF\) Safety factor -
\(KL/r\) Slenderness ratio -

Method and standards

Euler buckling.

Where it is used

  • Long-stroke cylinders.
  • Checking a cylinder after a mounting change.

Common mistakes

  • Using retracted length.
  • Using Euler for short stocky rods.

Assumptions and limits

  • Rod only. With no yield strength Euler is used for any slenderness (an overestimate for short rods, flagged below KL/r 100); with σ_y the Johnson parabola applies below the transition slenderness.
  • Theoretical K (0.5, 0.7, 1, 2). Design practice often uses larger values for imperfect fixity (for example 0.65 and 0.8 for the fixed–fixed and fixed–pinned cases).
  • A safety factor below 1 (buckles) or below 3 is flagged.

References

  • Euler column buckling with effective length factors (definitions)

Questions and answers

Which mounting is worst?

A cylinder fixed at one end with the rod end free to swing (K = 2) buckles at a quarter of the pinned–pinned load.

What length to use?

The fully extended distance from the mounting point to the load connection.

What do the defaults represent?

A 50 mm rod, 1.5 m extended, fixed–free, pushing 80 kN.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.