FireCADCalc

Fan Sound Power, Blade-Passing Frequency and Sound Pressure

Fan sound power level from a specific sound power level, flow and pressure, the blade-passing frequency and the sound pressure level at a distance.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 10 m3/s, 1500 Pa, 10 blades, 10 mQuiet low-pressure fan 300 Pa, free fieldID fan 3000 Pa, 50 m3/s, 30 m

Accepted: 0 to 80
Accepted: 3.6 to 36,000,000 m³/h
Accepted: 0.10197 to 10,197 mmWC
Accepted: 2 to 60
Accepted: 9.5493 to 9,549.3 rpm
Accepted: 0.5 to 1,000 m

Results

L_W = L_Ws + 10 log Q + 20 log Δp (Q in m³/s, Δp in Pa): sound power rises 6 dB for each doubling of pressure and 3 dB for each doubling of flow. Blade-passing tone at zn. Sound pressure by spherical or hemispherical spreading without room effects.

Sound power level (dB)118.53
Blade-passing frequency198.00Hz
Sound pressure level at r (dB)81.008

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 m3/s, 1500 Pa, 10 blades, 10 m. The inputs, in the units selected above:

InputValue
Specific sound power level (from maker or reference data, dB)30.000 -
Volume flow36,000 m³/h
Fan pressure152.96 mmWC
Number of blades10.000 -
Speed1,480.0 rpm
Distance from the fan (free field)10.000 m
RadiationHemispherical (on a hard floor)

Applying the formula below gives:

ResultValue
Sound power level (dB)103.52
Blade-passing frequency246.67 Hz
Sound pressure level at r (dB)75.540

Open this example in the calculator and change any input.

Formula

\(L_W = L_{Ws} + 10\log_{10}Q + 20\log_{10}\Delta p, \quad f_{BP} = \frac{zn}{60}, \quad L_p = L_W - 10\log_{10}(2\pi r^2)\)

Variables

Symbol Meaning SI unit
\(L_{Ws}\) Specific sound power level (from maker or reference data, dB) -
\(Q\) Volume flow m³/s
\(\Delta p\) Fan pressure Pa
\(z\) Number of blades -
\(n\) Speed rad/s
\(r\) Distance from the fan (free field) m
\(\text{field}\) Radiation -
\(L_W\) Sound power level (dB) -
\(f_{BP}\) Blade-passing frequency 1/s
\(L_p\) Sound pressure level at r (dB) -

Method and standards

Fan noise estimate.

Where it is used

  • Early noise screening of fan selections.
  • Silencer requirement estimates.

Common mistakes

  • Mixing specific sound power references and units.
  • Ignoring duct and room acoustics.

Assumptions and limits

  • Specific sound power from data; free-field spreading.

References

  • Specific sound power method for fans

Questions and answers

Why does pressure matter more than flow for noise?

Sound power grows with the square of pressure (20 log) but only linearly with flow (10 log); high-pressure fans are noisier.

Where does the tonal noise come from?

Each blade passing the cut-off or a strut makes a pressure pulse at the blade-passing frequency and its harmonics.

What do the defaults represent?

An illustrative 10-blade fan at 1,480 rpm moving 10 m³/s at 1,500 Pa with a specific sound power level of 30 dB, heard at 10 m on a hard floor.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bleier, Fan Handbook: Selection, Application and Design (McGraw-Hill, 1998)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.