FireCADCalc

Fan Specific Speed, Specific Diameter and Duty Coefficients

Dimensionless specific speed and specific diameter of a fan duty, with flow and pressure coefficients, to compare fan types and check a selection.

Thermal power plantProcess steam and utilities

Inputs

Examples: Illustrative 10 m3/s, 1500 Pa, 1480 rpm, 0.9 mAxial 40 m3/s, 400 Pa, 980 rpm, 1.8 mPressure blower 1 m3/s, 8000 Pa, 2950 rpm, 0.8 m

Accepted: 3.6 to 36,000,000 m³/h
Accepted: 0.10197 to 10,197 mmWC
Accepted: 0.1 to 5 kg/m³
Accepted: 9.5493 to 9,549.3 rpm
Accepted: 0.05 to 10 m

Results

ω in rad/s, n in rev/s for φ and ψ. Low specific speed and large specific diameter point to centrifugal fans (high pressure, low flow); high specific speed and small specific diameter to mixed-flow and axial fans. Good designs lie near the Cordier line of ω_s against D_s.

Specific speed ω√Q/(Δp/ρ)^¾2.3314
Specific diameter D(Δp/ρ)^¼/√Q1.6923
Flow coefficient Q/(nD³)0.55611
Pressure coefficient Δp/(ρn²D²)2.5363
Tip speed69.743m/s

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 10 m3/s, 1500 Pa, 1480 rpm, 0.9 m. The inputs, in the units selected above:

InputValue
Volume flow36,000 m³/h
Fan total pressure rise152.96 mmWC
Gas density1.2000 kg/m³
Rotational speed1,480.0 rpm
Impeller diameter0.90000 m

Applying the formula below gives:

ResultValue
Specific speed ω√Q/(Δp/ρ)^¾2.3314
Specific diameter D(Δp/ρ)^¼/√Q1.6923
Flow coefficient Q/(nD³)0.55611
Pressure coefficient Δp/(ρn²D²)2.5363
Tip speed69.743 m/s

Open this example in the calculator and change any input.

Formula

\(\omega_s = \frac{\omega\sqrt Q}{(\Delta p/\rho)^{3/4}}, \quad D_s = \frac{D(\Delta p/\rho)^{1/4}}{\sqrt Q}, \quad \varphi = \frac{Q}{nD^3}, \quad \psi = \frac{\Delta p}{\rho n^2D^2}\)

Variables

Symbol Meaning SI unit
\(Q\) Volume flow m³/s
\(\Delta p_t\) Fan total pressure rise Pa
\(\rho\) Gas density kg/m³
\(n\) Rotational speed rad/s
\(D\) Impeller diameter m
\(\omega_s\) Specific speed ω√Q/(Δp/ρ)^¾ -
\(D_s\) Specific diameter D(Δp/ρ)^¼/√Q -
\(\varphi\) Flow coefficient Q/(nD³) -
\(\psi\) Pressure coefficient Δp/(ρn²D²) -
\(u\) Tip speed m/s

Method and standards

Turbomachine similarity.

Where it is used

  • Fan selection and comparison.
  • Scaling test data to other sizes.

Common mistakes

  • Mixing rpm and rad/s.
  • Using static instead of total pressure.

Assumptions and limits

  • Incompressible flow.

References

  • Similarity parameters of turbomachines

Questions and answers

Why use specific speed?

It combines flow, pressure and speed into one number that is the same for geometrically similar fans, so it shows which fan type suits a duty.

What does the pressure coefficient show?

How hard the impeller works for its tip speed; backward-curved centrifugal fans have high ψ, axial fans low ψ.

What do the defaults represent?

An illustrative 10 m³/s at 1,500 Pa total pressure, air at 1.2 kg/m³, 1,480 rpm and a 0.9 m impeller.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Bleier, Fan Handbook: Selection, Application and Design (McGraw-Hill, 1998)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.