Fan and Motor Run-Up (Acceleration) Time

Time for a motor to accelerate a fan to speed against its square-law load torque from inertias, belt ratio and the motor's average accelerating torque.

Thermal power plantProcess steam and utilitiesSugar mill and cogeneration

Inputs

Examples: Illustrative 120 kg m2 ID fan, belt driveDirect-drive FD fanLarge slow ID fan, damper open

Accepted: 0.01 to 100,000 kg·m²
Accepted: 0.001 to 10,000 kg·m²
Accepted: 95.493 to 3,819.7 rpm
Accepted: 95.493 to 3,819.7 rpm
Accepted: 0.1 to 20,000 kW
Accepted: 0.1 to 20,000 kW
Accepted: 0.5 to 4

Results

J_eq dω/dt = T_m − T_L(ω/ω_m)² with constant average motor torque integrates to t = J_eq/√(aT_m)·artanh(ω_m√(a/T_m)), a = T_L/ω_m². Large induced-draught fans can take 20–60 s; compare with the motor's permitted locked-rotor (hot) time and start the fan against a closed damper or inlet vanes to cut T_L.

Inertia referred to the motor shaft59.333kg·m²
Average motor torque3,241.0N·m
Fan load torque at full speed (motor shaft)1,607.6N·m
Run-up time3.5401s
Kinetic energy at speed717.43kJ

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 kg m2 ID fan, belt drive. The inputs, in the units selected above:

InputValue
Fan rotor inertia120.00 kg·m²
Motor rotor inertia6.0000 kg·m²
Fan speed990.00 rpm
Motor speed1,485.0 rpm
Fan shaft power at full speed250.00 kW
Motor rated power315.00 kW
Average motor torque during run-up (× rated torque)1.6000 -

Applying the formula below gives:

ResultValue
Inertia referred to the motor shaft59.333 kg·m²
Average motor torque3,241.0 N·m
Fan load torque at full speed (motor shaft)1,607.6 N·m
Run-up time3.5401 s
Kinetic energy at speed717.43 kJ

Open this example in the calculator and change any input.

Formula

\(J_{eq} = J_m + J_f\left(\frac{n_f}{n_m}\right)^2, \quad t_a = \frac{J_{eq}}{\sqrt{aT_m}}\tanh^{-1}\left(\omega_m\sqrt{\frac a{T_m}}\right), \quad a = \frac{T_L}{\omega_m^2}\)

Variables

Symbol Meaning SI unit
\(J_f\) Fan rotor inertia kg·m²
\(J_m\) Motor rotor inertia kg·m²
\(n_f\) Fan speed rad/s
\(n_m\) Motor speed rad/s
\(P_f\) Fan shaft power at full speed W
\(P_m\) Motor rated power W
\(k_T\) Average motor torque during run-up (× rated torque) -
\(J_{eq}\) Inertia referred to the motor shaft kg·m²
\(T_m\) Average motor torque N·m
\(T_L\) Fan load torque at full speed (motor shaft) N·m
\(t_a\) Run-up time s
\(E_k\) Kinetic energy at speed J

Method and standards

Run-up time.

Where it is used

  • Motor selection for high-inertia fans.
  • Checking starting against motor thermal limits.

Common mistakes

  • Referring fan inertia without the speed ratio squared.
  • Using breakdown torque as the average.

Assumptions and limits

  • Constant average motor torque; square-law fan torque.

References

  • Rotor acceleration against a square-law load

Questions and answers

Why do large fans need special motors?

Their inertia makes run-up long; the motor's rotor must survive the heat of a long start.

How does a closed damper help?

It cuts the fan's air load during starting, so more motor torque goes into acceleration.

What do the defaults represent?

An illustrative 120 kg·m² fan at 990 rpm belt-driven from a 315 kW, 1,485 rpm motor (6 kg·m²), absorbing 250 kW, motor averaging 1.6 times rated torque.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Jorgensen (ed.), Fan Engineering, 9th ed. (Buffalo Forge / Howden, 1999), Bleier, Fan Handbook: Selection, Application and Design (McGraw-Hill, 1998)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.