Vacuum Pump-Down Time

Time to evacuate a vessel from one pressure to another with a vacuum pump of constant effective pumping speed, and the speed needed for a target time.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: 5 m³, 250 m³/h, atmosphere to 10 mbar; 10 min wantedCondenser 50 m³, 1 000 m³/h, to 100 mbar; 30 minDryer 2 m³, 60 m³/h, to 1 mbar; 1 h

Results

Constant speed and no leaks or outgassing: valid in the rough vacuum range. Pumping speed falls near the pump's ultimate pressure, and piping lowers the effective speed.

Pump-down time (V/S) ln(p₁/p₂)13.842min
Pumping speed needed for the time wanted13.842m³/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 5 m³, 250 m³/h, atmosphere to 10 mbar; 10 min wanted. The inputs, in the units selected above:

InputValue
Volume of the vessel and piping5.0000 m³
Effective pumping speed at the vessel250.00 m³/h
Starting pressure (absolute)1,013.2 mbar
Target pressure (absolute)10.000 mbar
Time wanted (for the speed needed)10.000 min

Applying the formula below gives:

ResultValue
Pump-down time (V/S) ln(p₁/p₂)5.5420 min
Pumping speed needed for the time wanted138.55 m³/h

Open this example in the calculator and change any input.

Formula

\(t = \frac{V}{S}\ln\frac{p_1}{p_2}\)

Variables

Symbol Meaning SI unit
\(V\) Volume of the vessel and piping m³
\(S\) Effective pumping speed at the vessel m³/s
\(p_1\) Starting pressure (absolute) Pa
\(p_2\) Target pressure (absolute) Pa
\(t_w\) Time wanted (for the speed needed) s
\(t\) Pump-down time (V/S) ln(p₁/p₂) s
\(S_{req}\) Pumping speed needed for the time wanted m³/s

Method and standards

Mass balance with constant volumetric speed.

Where it is used

  • Vacuum dryers, condensers and evaporators.
  • Pump selection.

Common mistakes

  • Pump nameplate speed instead of effective speed.
  • Ignoring leakage.

Assumptions and limits

  • Valid in the rough vacuum range (down to about 1 mbar); the page warns for lower targets, where outgassing and leakage set the time.

  • Rough vacuum, no gas load.

References

  • Pump-down equation for constant pumping speed (vacuum technology texts)

Questions and answers

5 m³ from atmospheric to 10 mbar with 250 m³/h?

5.5 minutes.

Why logarithmic?

Each pass removes the same share of the remaining gas.

Why does it take longer in practice?

Leaks, outgassing and falling pump speed at low pressure.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.