Compressor Free Air Delivery at Site Altitude and Temperature

Mass flow and free air delivery of a compressor at site altitude and intake temperature compared with its rating, at constant intake volume.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationChemical and fertiliserPulp and paperFood, dairy and textile

Inputs

Examples: 10 m³/min at 1,500 m, 35 °CSea level hot day 45 °C

Results

Intake volume stays about the same, so mass flow follows intake density. Positive-displacement compressors also lose a little volumetric efficiency at higher pressure ratios; centrifugal machines change more.

Site ambient pressure (ISA)101.33kPa
Mass flow ratio92.142%
Delivery at site, as a volume at the rated intake conditions (mass-based)9.2142m³/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 10 m³/min at 1,500 m, 35 °C. The inputs, in the units selected above:

InputValue
Rated FAD (at rated intake)10.000 m³/min
Rated intake pressure101.33 kPa
Rated intake temperature20.000 °C
Site altitude1,500.0 m
Site intake temperature35.000 °C

Applying the formula below gives:

ResultValue
Site ambient pressure (ISA)84.556 kPa
Mass flow ratio79.388 %
Delivery at site, as a volume at the rated intake conditions (mass-based)7.9388 m³/min

Open this example in the calculator and change any input.

Formula

\(p_s = p_0\left(1 - \frac{L z}{T_0}\right)^{g_0 M/(R^* L)}\ \text{(ISO 2533)}, \quad \frac{\dot m_s}{\dot m_r} = \frac{p_s}{p_r}\frac{T_r}{T_s}\)

Variables

Symbol Meaning SI unit
\(\dot V_r\) Rated FAD (at rated intake) m³/s
\(p_r\) Rated intake pressure Pa
\(T_r\) Rated intake temperature K
\(z\) Site altitude m
\(T_s\) Site intake temperature K
\(p_s\) Site ambient pressure (ISA) Pa
\(\dot m_s/\dot m_r\) Mass flow ratio -
\(\dot V_{FAD,ref}\) Delivery at site, as a volume at the rated intake conditions (mass-based) m³/s

Method and standards

Density ratio.

Where it is used

  • Compressor selection for hill sites.
  • Hot-season capacity checks.

Common mistakes

  • Comparing FAD at different reference conditions.
  • Ignoring intake temperature in plant rooms.

Assumptions and limits

  • Constant intake volume: the site FAD (volume at site intake) stays near the rated value; the output is the site mass flow expressed as a volume at the rated intake conditions.
  • Site pressure from FireCAD's ISO 2533 troposphere (p₀ 101 325 Pa, T₀ 288.15 K, L 0.0065 K/m).

References

  • ISA pressure–altitude relation (ISO 2533) and ideal-gas density (definitions)

Questions and answers

Why does altitude cut output?

Thinner air carries less mass per cubic metre drawn in; users need mass, not intake volume.

How much per 1,000 m?

About 11–12 % less mass flow, before temperature effects.

What do the defaults represent?

A 10 m³/min compressor at 1,500 m with 35 °C intake.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.