Worked example
Example: SMAW 28 V, 250 A, 300 mm/min, k 1 (arc energy). The inputs, in the units selected above:
| Input | Value |
|---|---|
| Arc voltage | 28.000 V |
| Welding current | 250.00 A |
| Travel speed | 300.00 mm/min |
| Thermal efficiency factor of the process | 100.00 % |
Applying the formula below gives:
| Result | Value |
|---|---|
| Heat input (kJ/mm) | 1.4000 |
| Arc energy (kJ/mm) | 1.4000 |
| Heat input (kJ/in) | 35.560 |
Open this example in the calculator and change any input.
Formula
\(E = \frac{U\,I}{v} \qquad Q = k\,E\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(U\) | arc voltage | V |
| \(I\) | welding current | A |
| \(v\) | travel speed | m/s |
| \(k\) | thermal efficiency factor | – |
| \(Q\) | heat input | kJ/mm |
| \(E\) | arc energy | kJ/mm |
| \(Q_{in}\) | heat input | kJ/in |
Method and standards
Arc energy and heat input as defined in EN ISO 1011-1 and ISO/TR 17671-1.
Where it is used
- Writing and checking WPS limits.
- Toughness-critical welds.
- Preheat calculations.
Common mistakes
- Using wire feed speed for travel speed.
- Averaging voltage of pulsed processes.
- Applying the wrong efficiency factor.
Assumptions and limits
- Steady arc; for pulsed processes use instantaneous energy.
- With the default k = 1 the heat input equals the arc energy; enter the process factor (for example about 0.8 for GMAW) to report heat input.
References
- EN ISO 1011-1 / ISO/TR 17671-1 (arc energy and heat input)
Questions and answers
What is the arc energy at 28 V, 250 A and 300 mm/min?
1.4 kJ/mm (35.6 kJ/in).
Arc energy or heat input?
Heat input is arc energy times the process thermal efficiency factor from your code; enter 1 for arc energy.
Why does heat input matter?
It sets cooling rate: too low risks hardness and cracking, too high lowers toughness.
Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.