FireCADCalc

Welding Machine Duty Cycle at Another Current

Allowable duty cycle of a welding power source at a different current from its rated current and duty cycle, and its 100 % duty current.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 300 A / 60 % run at 250 A400 A / 35 % at 450 A200 A / 60 % at 120 A (capped)

Results

Heating scales with I² in the transformer and rectifier; do not exceed the machine's maximum current even at low duty.

Allowable duty cycle at I₂86.400%
Current at 100 % duty232.38A
Arc-on minutes in a 10-minute cycle8.6400min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 300 A / 60 % run at 250 A. The inputs, in the units selected above:

InputValue
Rated current300.00 A
Rated duty cycle60.000 %
Required current250.00 A

Applying the formula below gives:

ResultValue
Allowable duty cycle at I₂86.400 %
Current at 100 % duty232.38 A
Arc-on minutes in a 10-minute cycle8.6400 min

Open this example in the calculator and change any input.

Formula

\(D_2 = D_1\left(\frac{I_1}{I_2}\right)^2, \quad I_{100} = I_1\sqrt{D_1}\)

Variables

Symbol Meaning SI unit
\(I_1\) Rated current A
\(D_1\) Rated duty cycle -
\(I_2\) Required current A
\(D_2\) Allowable duty cycle at I₂ -
\(I_{100}\) Current at 100 % duty A
\(t_{on}\) Arc-on minutes in a 10-minute cycle s

Method and standards

I²t heating.

Where it is used

  • Choosing a welding set.
  • Planning continuous welding (SAW, cladding).

Common mistakes

  • Ignoring ambient temperature derating.
  • Running above maximum current.

Assumptions and limits

  • 10-minute cycle; thermal equilibrium.
  • Currents above the rated current are extrapolated by the I² rule, which makers do not support; never exceed the machine's maximum current.

References

  • Equal heating: I₁²D₁ = I₂²D₂ (IEC 60974-1 rating principle, 10-minute cycle)

Questions and answers

What does 60 % duty at 300 A mean?

The machine can weld at 300 A for 6 minutes in every 10 without overheating.

Can I weld longer at lower current?

Yes: duty rises with the square of the current ratio, up to 100 %.

What do the defaults represent?

A 300 A / 60 % machine run at 250 A.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.