FireCADCalc

Liquidus Temperature of Low-Alloy Steel from Composition

Liquidus temperature of a low-alloy steel from carbon and alloy contents, with the delta-iron form below 0.5 % C and the austenite form from 0.5 to 1.0 % C.

Inputs

Examples: 0.20 C, 0.25 Si, 0.80 Mn structural steel0.80 C rail steel0.04 C low-carbon sheet

Accepted: 0 to 1 %
Accepted: 0 to 3 %
Accepted: 0 to 3 %
Accepted: 0 to 0.2 %
Accepted: 0 to 0.2 %
Accepted: 0 to 5 %
Accepted: 0 to 5 %
Accepted: 0 to 2 %
Accepted: 0 to 2 %
Accepted: 0 to 2 %

Results

The alloy coefficients (°C per %): Si −14, Mn −4, P −30, S −45, Cr −1.5, Ni −3.5, Mo −5, V −4, Al −2.5, assumed additive. Tapping and casting superheats are set above this liquidus.

Liquidus temperature1,532.3°C
Depression by alloying elements-1.8000K
Equation used (1: δ-iron, below 0.5 % C; 2: austenite, 0.5-1.0 % C)1.0000

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.20 C, 0.25 Si, 0.80 Mn structural steel. The inputs, in the units selected above:

InputValue
Carbon0.20000 %
Silicon0.25000 %
Manganese0.80000 %
Phosphorus0.020000 %
Sulphur0.010000 %
Chromium0.10000 %
Nickel0.10000 %
Molybdenum0.020000 %
Vanadium0 %
Aluminium0.030000 %

Applying the formula below gives:

ResultValue
Liquidus temperature1,514.0 °C
Depression by alloying elements-8.4250 K
Equation used (1: δ-iron, below 0.5 % C; 2: austenite, 0.5-1.0 % C)1.0000

Open this example in the calculator and change any input.

Formula

\(T_L = 1537 - 73.1[\%C] + \sum a_i[\%X_i]\ (\%C < 0.5), \quad T_L = 1531 - 61.5[\%C] + \sum a_i[\%X_i]\ (0.5 \le \%C \le 1.0)\)

Variables

Symbol Meaning SI unit
\([\%C]\) Carbon -
\([\%Si]\) Silicon -
\([\%Mn]\) Manganese -
\([\%P]\) Phosphorus -
\([\%S]\) Sulphur -
\([\%Cr]\) Chromium -
\([\%Ni]\) Nickel -
\([\%Mo]\) Molybdenum -
\([\%V]\) Vanadium -
\([\%Al]\) Aluminium -
\(T_L\) Liquidus temperature K
\(\sum a_i[\%X_i]\) Depression by alloying elements K
\(\text{form}\) Equation used (1: δ-iron, below 0.5 % C; 2: austenite, 0.5-1.0 % C) -

Method and standards

Additive liquidus depression from binary Fe-X systems.

Where it is used

  • Setting tap and tundish temperatures.
  • Superheat control in continuous casting.

Common mistakes

  • Using it for stainless or high-alloy steels.

Assumptions and limits

  • Low-alloy steels; coefficients additive.

Questions and answers

Why two equations?

Below about 0.5 % C solidification starts as delta ferrite; from 0.5 to 1.0 % C it starts as austenite, which changes the slope and intercept for carbon.

How is the superheat used?

Tundish and ladle temperatures are specified as a superheat above this liquidus, typically 20-40 K for continuous casting.

What do the defaults represent?

A 0.20 % C, 0.25 % Si, 0.80 % Mn structural steel with small residuals: liquidus about 1,514 °C.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fruehan (ed.), The Making, Shaping and Treating of Steel, 11th ed., Steelmaking and Refining Volume (AISE Steel Foundation, 1998), sec. 2.4.4, eqs. 2.4.29-2.4.30

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.