Hydrogen and Nitrogen Solubility in Liquid Steel (Sieverts' Law)

Equilibrium hydrogen and nitrogen contents of liquid iron at a gas partial pressure and temperature, and the vacuum needed to reach target levels.

Inputs

Examples: 1,600 C, 1 atm H2 and air nitrogen1,650 C, moist atmosphere 0.01 atm H21,550 C degasser 1 mbar

Accepted: 1,499.8 to 1,799.8 °C
Accepted: 0 to 1.9738 atm
Accepted: 0 to 1.9738 atm
Accepted: 0.01 to 100 ppm
Accepted: 0.1 to 1,000 ppm

Results

Ideal (Sieverts) solubility in pure liquid iron; alloying elements change it through interaction coefficients. In practice hydrogen removal is limited by water vapour and the mass transfer in the degasser, and nitrogen removal is slow, especially at high sulphur.

Equilibrium hydrogen0.75507ppm
Equilibrium nitrogen10.081ppm
Hydrogen constant (ppm/atm½)24.035
Nitrogen constant (ppm/atm½)453.82
H₂ pressure in equilibrium with the target hydrogen1.7540mbar
N₂ pressure in equilibrium with the target nitrogen1.9679mbar

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 1,600 C, 1 atm H2 and air nitrogen. The inputs, in the units selected above:

InputValue
Melt temperature1,600.0 °C
Hydrogen partial pressure1.0000 atm
Nitrogen partial pressure0.79000 atm
Target hydrogen2.0000 ppm
Target nitrogen40.000 ppm

Applying the formula below gives:

ResultValue
Equilibrium hydrogen25.625 ppm
Equilibrium nitrogen405.93 ppm
Hydrogen constant (ppm/atm½)25.625
Nitrogen constant (ppm/atm½)456.70
H₂ pressure in equilibrium with the target hydrogen6.1723 mbar
N₂ pressure in equilibrium with the target nitrogen7.7726 mbar

Open this example in the calculator and change any input.

Formula

\(\log\frac{[\text{ppm H}]}{p_{H_2}^{1/2}} = -\frac{1900}{T} + 2.423, \quad \log\frac{[\text{ppm N}]}{p_{N_2}^{1/2}} = -\frac{188}{T} + 2.760\)

Variables

Symbol Meaning SI unit
\(T\) Melt temperature K
\(p_{H_2}\) Hydrogen partial pressure Pa
\(p_{N_2}\) Nitrogen partial pressure Pa
\([H]^*\) Target hydrogen -
\([N]^*\) Target nitrogen -
\([H]\) Equilibrium hydrogen -
\([N]\) Equilibrium nitrogen -
\(K_H\) Hydrogen constant (ppm/atm½) -
\(K_N\) Nitrogen constant (ppm/atm½) -
\(p_{H_2}^*\) H₂ pressure in equilibrium with the target hydrogen Pa
\(p_{N_2}^*\) N₂ pressure in equilibrium with the target nitrogen Pa

Method and standards

Sieverts' law with published solubility constants for liquid iron.

Where it is used

  • Vacuum degasser targets.
  • Assessing hydrogen pick-up from wet additions.

Common mistakes

  • Using total pressure instead of the gas partial pressure.
  • Pressure in pascals in the formula, which uses atm.

Assumptions and limits

  • Pure iron; dilute solutions.

Questions and answers

Why the square root of pressure?

Diatomic gases dissolve as atoms, ½H₂ = [H], so the dissolved content is proportional to the square root of the partial pressure (Sieverts' law).

How low must the vacuum be?

For 2 ppm of hydrogen at 1,600 °C the equilibrium H₂ pressure is about 6 mbar; degassers run at about 1 mbar to give a driving force.

What do the defaults represent?

Liquid iron at 1,600 °C under 1 atm of H₂ or air nitrogen (0.79 atm): 25.6 ppm H and 406 ppm N; targets of 2 ppm H and 40 ppm N need 6.2 mbar of H₂ and 7.8 mbar of N₂.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fruehan (ed.), The Making, Shaping and Treating of Steel, 11th ed., Steelmaking and Refining Volume (AISE Steel Foundation, 1998), sec. 2.4.2, Table 2.9, eqs. 2.4.9-2.4.10

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.