FireCADCalc

Carbon-Oxygen Equilibrium in Liquid Steel and Oxygen Saturation

Dissolved oxygen in equilibrium with carbon at a CO pressure, [%C][ppm O] = 20 pCO, the effect of vacuum and the oxygen solubility limit with liquid iron oxide.

Inputs

Examples: 0.05 % C at 1,600 C, 1 and 0.2 atmBOF tap 0.04 % C, 1,650 CRH 0.02 % C under 0.05 atm, 1,600 C

Accepted: 1E-4 to 1 %
Accepted: 9.869E-5 to 4.9346 atm
Accepted: 9.869E-6 to 0.98692 atm
Accepted: 1,526.8 to 1,826.8 °C

Results

K = 20 is not very sensitive to temperature and holds for low-alloy steel below about 1 % C. Lowering the CO pressure by vacuum lowers the oxygen in equilibrium with a given carbon, which is how RH and VD units decarburise without oxygen.

Equilibrium oxygen at p_CO1,000.0ppm
Equilibrium oxygen at the vacuum CO pressure50.000ppm
Oxygen solubility with liquid FeO0.22855%
Carbon below which iron oxide forms (at p_CO)0.008751%

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.05 % C at 1,600 C, 1 and 0.2 atm. The inputs, in the units selected above:

InputValue
Carbon content0.050000 %
CO partial pressure1.0000 atm
CO pressure under vacuum0.20000 atm
Melt temperature1,600.0 °C

Applying the formula below gives:

ResultValue
Equilibrium oxygen at p_CO400.00 ppm
Equilibrium oxygen at the vacuum CO pressure80.000 ppm
Oxygen solubility with liquid FeO0.22855 %
Carbon below which iron oxide forms (at p_CO)0.008751 %

Open this example in the calculator and change any input.

Formula

\([\%C][\text{ppm O}] = 20\,p_{CO}, \quad \log[\%O]_{sat} = -\frac{6380}{T} + 2.765\)

Variables

Symbol Meaning SI unit
\([\%C]\) Carbon content -
\(p_{CO}\) CO partial pressure Pa
\(p_{CO}'\) CO pressure under vacuum Pa
\(T\) Melt temperature K
\([O]\) Equilibrium oxygen at p_CO -
\([O]'\) Equilibrium oxygen at the vacuum CO pressure -
\([\%O]_{sat}\) Oxygen solubility with liquid FeO -
\([\%C]_{min}\) Carbon below which iron oxide forms (at p_CO) -

Method and standards

Carbon-oxygen equilibrium in liquid iron.

Where it is used

  • BOF and EAF end-point oxygen.
  • Vacuum decarburisation of ultra-low-carbon steel.

Common mistakes

  • Using it at high carbon without activity corrections.
  • Entering p_CO in bar or kPa into the atm form.

Assumptions and limits

  • Low-alloy steel below 1 % C; equilibrium, not kinetics.

Questions and answers

Why does vacuum help decarburisation?

C + O = CO(g): lowering p_CO shifts the equilibrium so that the same carbon coexists with less oxygen, and carbon reacts with the dissolved oxygen without adding more.

What is the oxygen saturation?

The highest oxygen liquid iron can hold before liquid iron oxide separates: about 0.23 % at 1,600 °C (Taylor and Chipman).

What do the defaults represent?

0.05 % C at 1,600 °C: 400 ppm O at 1 atm CO and 80 ppm at 0.2 atm; oxygen saturation is 0.23 %, so iron oxide forms below about 0.009 % C at 1 atm.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fruehan (ed.), The Making, Shaping and Treating of Steel, 11th ed., Steelmaking and Refining Volume (AISE Steel Foundation, 1998), sec. 2.4.2.2, eq. 2.4.13 and sec. 2.4.5, eq. 2.4.31

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.