FireCADCalc

RH Degasser Decarburisation Time and Rate Constant

Overall decarburisation rate constant of an RH degasser from circulation rate, vessel steel mass and reaction constant, and the time to reach a carbon target.

Inputs

Examples: 250 t ladle, 120 t/min300 t, large snorkels 200 t/min150 t, slow 60 t/min

Accepted: 10 to 500 t
Accepted: 3.6 to 36,000 t/h
Accepted: 0.1 to 100 t
Accepted: 0.006 to 600 1/min
Accepted: 1 to 10,000 ppm
Accepted: 0 to 1,000 ppm
Accepted: 0.1 to 10,000 ppm

Results

When the circulation rate is low, K approaches Q/W and the rate is circulation-controlled; newer RH units have large snorkels for this reason. Hydrogen removal follows the same form with a larger vessel constant.

Overall rate constant0.400001/min
Circulation limit Q/W0.666671/min
Time to the target carbon8.4610min
Carbon after 10 min10.403ppm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 250 t ladle, 120 t/min. The inputs, in the units selected above:

InputValue
Steel in the ladle250.00 t
Metal circulation rate7,200.0 t/h
Steel in the RH vessel15.000 t
Decarburisation rate constant in the vessel15.000 1/min
Initial carbon350.00 ppm
Equilibrium carbon5.0000 ppm
Target carbon20.000 ppm

Applying the formula below gives:

ResultValue
Overall rate constant0.31304 1/min
Circulation limit Q/W0.48000 1/min
Time to the target carbon10.016 min
Carbon after 10 min20.076 ppm

Open this example in the calculator and change any input.

Formula

\(\ln\frac{[\%C] - [\%C]_e}{[\%C]_0 - [\%C]_e} = -Kt, \quad K = \frac{Q}{W}\left(\frac{kW_{RH}}{kW_{RH} + Q}\right)\)

Variables

Symbol Meaning SI unit
\(W\) Steel in the ladle kg
\(Q\) Metal circulation rate kg/s
\(W_{RH}\) Steel in the RH vessel kg
\(k\) Decarburisation rate constant in the vessel 1/s
\([\%C]_0\) Initial carbon -
\([\%C]_e\) Equilibrium carbon -
\([\%C]^*\) Target carbon -
\(K\) Overall rate constant 1/s
\(Q/W\) Circulation limit Q/W 1/s
\(t\) Time to the target carbon s
\([\%C]_{10}\) Carbon after 10 min -

Method and standards

Two-zone RH decarburisation model.

Where it is used

  • Planning ultra-low-carbon treatment times.
  • Assessing snorkel and lift-gas upgrades.

Common mistakes

  • Using the circulation rate in t/h with k in 1/min.
  • Ignoring the equilibrium carbon at the vessel pressure.

Assumptions and limits

  • Approximate solution; constant rate constant.

Questions and answers

What limits the rate?

Two resistances in series: the circulation that brings ladle steel to the vessel (Q/W) and the reaction in the vessel (k W_RH/W); K combines them.

How do I raise the rate?

Increase the circulation (lift gas, snorkel diameter), the steel held in the vessel or the reaction constant (lower pressure, more surface from argon).

What do the defaults represent?

250 t ladle, 120 t/min circulation, 15 t in the vessel and k = 15 min⁻¹: K = 0.31 min⁻¹ (Q/W 0.48), and 350 ppm C falls to 20 ppm in 10.0 min with 5 ppm at equilibrium.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Fruehan (ed.), The Making, Shaping and Treating of Steel, 11th ed., Steelmaking and Refining Volume (AISE Steel Foundation, 1998), sec. 2.11.2, eqs. 2.11.5-2.11.8

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.