FireCADCalc

Reheating Furnace Hearth Loading and Residence Time

Steel held on the hearth of a reheating furnace from its dimensions, stock thickness and coverage, the residence time at a throughput and the specific hearth rating.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 150 t/h walking beamBillet pusher 60 t/hForge batch-type 10 t/h

Accepted: 0.36 to 720 t/h
Accepted: 2 to 60 m
Accepted: 1 to 20 m
Accepted: 20 to 600 mm
Accepted: 30 to 100 %
Accepted: 7,000 to 8,000 kg/m³

Results

Steel on hearth = L·W·coverage·thickness·ρ; residence time = held mass / throughput. Residence time must cover heating to a uniform temperature, roughly in proportion to thickness (often 8–12 min per 10 mm for slabs heated from both faces); hearth ratings of about 400–700 kg/(m²·h) are usual for walking-beam furnaces.

Steel on the hearth45.216t
Residence time4.5216h
Hearth rating312.50kg/(m²·h)
Hearth area32.000m²

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 150 t/h walking beam. The inputs, in the units selected above:

InputValue
Throughput150.00 t/h
Effective hearth length30.000 m
Effective hearth width12.000 m
Stock thickness220.00 mm
Hearth coverage85.000 %
Steel density7,850.0 kg/m³

Applying the formula below gives:

ResultValue
Steel on the hearth528.46 t
Residence time3.5231 h
Hearth rating416.67 kg/(m²·h)
Hearth area360.00 m²

Open this example in the calculator and change any input.

Formula

\(m_h = LWft\rho, \quad t_r = \frac{m_h}{\dot m}, \quad \frac{\dot m}{A} = \frac{\dot m}{LW}\)

Variables

Symbol Meaning SI unit
\(\dot m\) Throughput kg/s
\(L\) Effective hearth length m
\(W\) Effective hearth width m
\(t\) Stock thickness m
\(f\) Hearth coverage -
\(\rho\) Steel density kg/m³
\(m_h\) Steel on the hearth kg
\(t_r\) Residence time s
\(\dot m/A\) Hearth rating kg/(m²·s)
\(A\) Hearth area m²

Method and standards

Hearth loading.

Where it is used

  • Rolling mill furnace capacity checks.
  • Changing stock sizes and rates.

Common mistakes

  • Counting the hearth length of the soak zone only.
  • Forgetting gaps between pieces (coverage).

Assumptions and limits

  • Uniform stock and coverage along the hearth.

References

  • Reheating furnace inventory relations

Questions and answers

Why is residence time tied to thickness?

Heat must conduct to the centre; heating time grows with thickness (and with its square for one-sided heating).

What limits throughput?

Hearth area times permissible rating, set by heating time, scale formation and burner capacity.

What do the defaults represent?

An illustrative 150 t/h walking-beam furnace with a 30 × 12 m hearth, 220 mm slabs at 85 % coverage.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.