Moulding Sand Permeability Number (AFS Test)

AFS permeability number of a rammed moulding sand specimen from the air volume, specimen size, pressure and time, and by the standard 3007.2/t formula.

Inputs

Examples: Standard AFS specimen, 25 sStandard specimen, fine sand 75 sDIN 50 mm specimen, 1000 cm3 at 10 cm, 9 s

Accepted: 10 to 10,000 cm³
Accepted: 0.5 to 20 cm
Accepted: 1 to 100 cm²
Accepted: 0.5 to 3,600 s
Accepted: 0.010197 to 101.97 cmWC

Results

The permeability number is the air flow (cm³/min) through a specimen 1 cm long and 1 cm² in section under 1 cm of water. The 3007.2/t formula applies only to the standard 2 in × 2 in AFS specimen, 2,000 cm³ of air and 10 cm water gauge.

Permeability number169.76
Standard-apparatus formula 3007.2/t334.13
Air flow through the specimen6.6667L/min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Standard AFS specimen, 25 s. The inputs, in the units selected above:

InputValue
Volume of air passed2,000.0 cm³
Specimen height5.0800 cm
Specimen cross-section20.268 cm²
Time for the air to pass25.000 s
Pressure difference across the specimen10.000 cmWC

Applying the formula below gives:

ResultValue
Permeability number120.31
Standard-apparatus formula 3007.2/t120.29
Air flow through the specimen4.8000 L/min

Open this example in the calculator and change any input.

Formula

\(P = \frac{Vh}{a\,t\,p}\ \ (\text{cm}^3,\ \text{cm},\ \text{cm}^2,\ \text{min},\ \text{cm H}_2\text{O}), \quad P_{std} = \frac{3007.2}{t\,[\text{s}]}\)

Variables

Symbol Meaning SI unit
\(V\) Volume of air passed m³
\(h\) Specimen height m
\(a\) Specimen cross-section m²
\(t\) Time for the air to pass s
\(p\) Pressure difference across the specimen Pa
\(P\) Permeability number -
\(P_{std}\) Standard-apparatus formula 3007.2/t -
\(Q\) Air flow through the specimen m³/s

Method and standards

AFS permeability number.

Where it is used

  • Daily sand control in foundries.
  • Comparing sand mixes and gradings.

Common mistakes

  • Using the standard formula on a non-standard specimen.
  • Timing the wrong air volume.

Assumptions and limits

  • Laminar flow through the specimen.

Questions and answers

What permeability is normal?

Fine sands for light non-ferrous castings run at 20–60; greensand for iron 80–150; steel sands often above 150.

Why does permeability matter?

Steam and gases from the mould must escape through the sand; too low a number causes blows and scabs, too high a number lets metal penetrate.

What do the defaults represent?

The standard AFS test: 2,000 cm³ of air through a 2 in (5.08 cm) × 2 in specimen at 10 cm water gauge, taking 25 seconds.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Beeley, Foundry Technology, 2nd ed. (Butterworth-Heinemann, 2001), ch. 4 (permeability P = Vh/(atp); P = 3007.2/t for the standard apparatus)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.