Worked example
Example: Standard AFS specimen, 25 s. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Volume of air passed | 2,000.0 cm³ |
| Specimen height | 5.0800 cm |
| Specimen cross-section | 20.268 cm² |
| Time for the air to pass | 25.000 s |
| Pressure difference across the specimen | 10.000 cmWC |
Applying the formula below gives:
| Result | Value |
|---|---|
| Permeability number | 120.31 |
| Standard-apparatus formula 3007.2/t | 120.29 |
| Air flow through the specimen | 4.8000 L/min |
Open this example in the calculator and change any input.
Formula
\(P = \frac{Vh}{a\,t\,p}\ \ (\text{cm}^3,\ \text{cm},\ \text{cm}^2,\ \text{min},\ \text{cm H}_2\text{O}), \quad P_{std} = \frac{3007.2}{t\,[\text{s}]}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V\) | Volume of air passed | m³ |
| \(h\) | Specimen height | m |
| \(a\) | Specimen cross-section | m² |
| \(t\) | Time for the air to pass | s |
| \(p\) | Pressure difference across the specimen | Pa |
| \(P\) | Permeability number | - |
| \(P_{std}\) | Standard-apparatus formula 3007.2/t | - |
| \(Q\) | Air flow through the specimen | m³/s |
Method and standards
AFS permeability number.
Where it is used
- Daily sand control in foundries.
- Comparing sand mixes and gradings.
Common mistakes
- Using the standard formula on a non-standard specimen.
- Timing the wrong air volume.
Assumptions and limits
- Laminar flow through the specimen.
Questions and answers
What permeability is normal?
Fine sands for light non-ferrous castings run at 20–60; greensand for iron 80–150; steel sands often above 150.
Why does permeability matter?
Steam and gases from the mould must escape through the sand; too low a number causes blows and scabs, too high a number lets metal penetrate.
What do the defaults represent?
The standard AFS test: 2,000 cm³ of air through a 2 in (5.08 cm) × 2 in specimen at 10 cm water gauge, taking 25 seconds.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Beeley, Foundry Technology, 2nd ed. (Butterworth-Heinemann, 2001), ch. 4 (permeability P = Vh/(atp); P = 3007.2/t for the standard apparatus)