Worked example
Example: Iron casting 0.6 m2 under 250 mm head. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Density of the liquid metal | 7,000.0 kg/m³ |
| Metal head above the mould surface (to the top of the sprue) | 250.00 mm |
| Projected area of the casting at the joint | 0.60000 m² |
| Mass of the cope (sand and box) | 400.00 kg |
| Volume of cores immersed in metal | 20.000 L |
| Core density | 1,500.0 kg/m³ |
| Casting volume (liquid) | 80.000 L |
| Superheat at pouring | 100.00 K |
| Liquid shrinkage per 100 °C of superheat | 1.6000 % |
| Cross-section of the feeder or sprue at the top | 314.00 cm² |
Applying the formula below gives:
| Result | Value |
|---|---|
| Force lifting the cope | 10.297 kN |
| Minimum total mass on the mould, cope included | 1,050.0 kg |
| Extra weights needed on the cope | 650.00 kg |
| Net upthrust on the cores | 1,078.7 N |
| Liquid contraction of the casting | 1.2800 L |
| Fall of the liquid level in the feeder | 40.764 mm |
Open this example in the calculator and change any input.
Formula
\(F = \rho ghA, \quad m_{min} = \rho hA, \quad F_{core} = (\rho - \rho_{core})gV_{core}, \quad \Delta h = \frac{V_c\beta_L\Delta T_{sh}/100}{A_f}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(\rho\) | Density of the liquid metal | kg/m³ |
| \(h\) | Metal head above the mould surface (to the top of the sprue) | m |
| \(A\) | Projected area of the casting at the joint | m² |
| \(m_{cope}\) | Mass of the cope (sand and box) | kg |
| \(V_{core}\) | Volume of cores immersed in metal | m³ |
| \(\rho_{core}\) | Core density | kg/m³ |
| \(V_c\) | Casting volume (liquid) | m³ |
| \(\Delta T_{sh}\) | Superheat at pouring | K |
| \(\beta_L\) | Liquid shrinkage per 100 °C of superheat | - |
| \(A_f\) | Cross-section of the feeder or sprue at the top | m² |
| \(F\) | Force lifting the cope | N |
| \(m_{min}\) | Minimum total mass on the mould, cope included | kg |
| \(m_{add}\) | Extra weights needed on the cope | kg |
| \(F_{core}\) | Net upthrust on the cores | N |
| \(\Delta V_L\) | Liquid contraction of the casting | m³ |
| \(\Delta h\) | Fall of the liquid level in the feeder | m |
Method and standards
Hydrostatics of the filled mould.
Where it is used
- Weighting and clamping moulds.
- Core support and chaplet design.
Common mistakes
- Ignoring the sprue height in the head.
- Forgetting the cope's own weight counts.
Assumptions and limits
- Rigid mould; static metal.
Questions and answers
Why does the head, not the casting weight, set the force?
Liquid metal transmits pressure ρgh to every surface of the cavity; the upward push on the cope is that pressure times the projected area, however thin the casting.
Why do cores float?
A sand core weighs about a fifth of the iron or steel it displaces, so the net upthrust is about four-fifths of the displaced metal's weight.
What do the defaults represent?
Grey iron or steel at 7,000 kg/m³ with 250 mm head over a 0.6 m² casting, a 400 kg cope, 20 L of cores at 1,500 kg/m³, and an 80 L casting with 100 °C superheat feeding through a 200 mm feeder.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Beeley, Foundry Technology, 2nd ed. (Butterworth-Heinemann, 2001), ch. 1 (forces acting on the mould; liquid contraction 1.0–2.5 % per 100 °C)