FireCADCalc

Ladle Steel Temperature Loss during Holding

Rate of temperature fall of liquid steel in a ladle from radiation off the top surface and conduction into the refractory, and the drop over a holding time.

Inputs

Examples: Illustrative 120 t ladle, slag coverOpen surface, no slagSmall 20 t ladle, cold lining

Accepted: 1 to 400 t
Accepted: 0.7 to 0.9 kJ/(kg·K)
Accepted: 1,499.8 to 1,699.8 °C
Accepted: 0.5 to 30 m²
Accepted: 5 to 100 %
Accepted: -0.15 to 999.85 °C
Accepted: 1 to 100 m²
Accepted: 0 to 100 kW/m²
Accepted: 1 to 166.67 min

Results

dT/dt = −[εσA_t(T⁴ − T₀⁴) + q_wA_w]/(mc_l), applied linearly over the holding time (rates change little over tens of kelvin). A good slag cover and a lid cut the radiation many times; refractory flux is highest in a cold ladle and falls as it soaks, so preheated, circulating ladles lose far less. Typical losses are 0.5–2 K/min.

Radiation from the top534.49kW
Loss to refractory270.00kW
Temperature fall rate2.9433K/min
Drop over the holding time44.149K

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 120 t ladle, slag cover. The inputs, in the units selected above:

InputValue
Steel mass120.00 t
Liquid steel specific heat0.82000 kJ/(kg·K)
Steel temperature1,600.0 °C
Free top surface area7.0000 m²
Effective emissivity of the surface (lower with slag cover)40.000 %
Surroundings temperature50.000 °C
Wetted refractory area30.000 m²
Heat flux into refractory15.000 kW/m²
Holding time30.000 min

Applying the formula below gives:

ResultValue
Radiation from the top1,952.9 kW
Loss to refractory450.00 kW
Temperature fall rate1.4652 K/min
Drop over the holding time43.955 K

Open this example in the calculator and change any input.

Formula

\(\dot T = \frac{\varepsilon\sigma A_t(T^4 - T_0^4) + q_wA_w}{mc_l}, \quad \Delta T = \dot Tt_h\)

Variables

Symbol Meaning SI unit
\(m\) Steel mass kg
\(c_l\) Liquid steel specific heat J/(kg·K)
\(T\) Steel temperature K
\(A_t\) Free top surface area m²
\(\varepsilon\) Effective emissivity of the surface (lower with slag cover) -
\(T_0\) Surroundings temperature K
\(A_w\) Wetted refractory area m²
\(q_w\) Heat flux into refractory W/m²
\(t_h\) Holding time s
\(\dot Q_r\) Radiation from the top W
\(\dot Q_w\) Loss to refractory W
\(\dot T\) Temperature fall rate K/s
\(\Delta T\) Drop over the holding time K

Method and standards

Ladle cooling.

Where it is used

  • Tapping temperature targets for casters.
  • Ladle practice improvements.

Common mistakes

  • Using the steel's emissivity for a slag-covered surface.
  • Ignoring refractory soak losses for cold ladles.

Assumptions and limits

  • Uniform bath temperature; constant losses over the hold.

References

  • Radiation and refractory heat balance

Questions and answers

Why does a slag cover help so much?

An open steel surface at 1,600 °C radiates hundreds of kW per square metre; slag and lids lower the effective emissivity and surface temperature.

Why do cold ladles lose more heat?

Dry, cold refractory absorbs heat fast at first; ladles kept hot in circulation absorb much less.

What do the defaults represent?

An illustrative 120 t heat at 1,600 °C with 7 m² of surface (ε 0.4 with slag), 30 m² of refractory at 15 kW/m², held 30 minutes.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

AISE, The Making, Shaping and Treating of Steel, 11th ed. (AISE Steel Foundation, 1998)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.