Worked example
Example: Illustrative 120 t ladle, slag cover. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Steel mass | 120.00 t |
| Liquid steel specific heat | 0.82000 kJ/(kg·K) |
| Steel temperature | 1,600.0 °C |
| Free top surface area | 7.0000 m² |
| Effective emissivity of the surface (lower with slag cover) | 40.000 % |
| Surroundings temperature | 50.000 °C |
| Wetted refractory area | 30.000 m² |
| Heat flux into refractory | 15.000 kW/m² |
| Holding time | 30.000 min |
Applying the formula below gives:
| Result | Value |
|---|---|
| Radiation from the top | 1,952.9 kW |
| Loss to refractory | 450.00 kW |
| Temperature fall rate | 1.4652 K/min |
| Drop over the holding time | 43.955 K |
Open this example in the calculator and change any input.
Formula
\(\dot T = \frac{\varepsilon\sigma A_t(T^4 - T_0^4) + q_wA_w}{mc_l}, \quad \Delta T = \dot Tt_h\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(m\) | Steel mass | kg |
| \(c_l\) | Liquid steel specific heat | J/(kg·K) |
| \(T\) | Steel temperature | K |
| \(A_t\) | Free top surface area | m² |
| \(\varepsilon\) | Effective emissivity of the surface (lower with slag cover) | - |
| \(T_0\) | Surroundings temperature | K |
| \(A_w\) | Wetted refractory area | m² |
| \(q_w\) | Heat flux into refractory | W/m² |
| \(t_h\) | Holding time | s |
| \(\dot Q_r\) | Radiation from the top | W |
| \(\dot Q_w\) | Loss to refractory | W |
| \(\dot T\) | Temperature fall rate | K/s |
| \(\Delta T\) | Drop over the holding time | K |
Method and standards
Ladle cooling.
Where it is used
- Tapping temperature targets for casters.
- Ladle practice improvements.
Common mistakes
- Using the steel's emissivity for a slag-covered surface.
- Ignoring refractory soak losses for cold ladles.
Assumptions and limits
- Uniform bath temperature; constant losses over the hold.
References
- Radiation and refractory heat balance
Questions and answers
Why does a slag cover help so much?
An open steel surface at 1,600 °C radiates hundreds of kW per square metre; slag and lids lower the effective emissivity and surface temperature.
Why do cold ladles lose more heat?
Dry, cold refractory absorbs heat fast at first; ladles kept hot in circulation absorb much less.
What do the defaults represent?
An illustrative 120 t heat at 1,600 °C with 7 m² of surface (ε 0.4 with slag), 30 m² of refractory at 15 kW/m², held 30 minutes.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
AISE, The Making, Shaping and Treating of Steel, 11th ed. (AISE Steel Foundation, 1998)