FireCADCalc

Furnace Wall Heat Storage and Steady Loss

Heat stored in a furnace wall at steady temperature profile and its steady conduction loss, showing how much a batch furnace must reheat its lining each cycle.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 230 mm firebrickCeramic fibre lining 200 mmInsulating brick 300 mm

Accepted: 0.5 to 5,000 m²
Accepted: 20 to 1,000 mm
Accepted: 100 to 3,000 kg/m³
Accepted: 0.6 to 1.3 kJ/(kg·K)
Accepted: 0.05 to 5 W/(m·K)
Accepted: 126.85 to 1,726.8 °C
Accepted: 6.85 to 226.85 °C
Accepted: -23.15 to 56.85 °C

Results

Linear steady profile: mean wall temperature (T_h + T_c)/2, stored heat ρcAL(T_mean − T₀); steady loss kA(T_h − T_c)/L. Dense brick stores many hours' worth of loss, which batch and intermittent furnaces lose every cycle; low-density fibre linings store a small fraction, so they suit intermittent firing even if their steady loss is similar.

Heat stored in the wall1,137.7MJ
Steady conduction loss74.400kW
Storage equal to hours of steady loss4.2476h
Lining mass2.0480t

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 230 mm firebrick. The inputs, in the units selected above:

InputValue
Wall area80.000 m²
Lining thickness230.00 mm
Lining density2,000.0 kg/m³
Lining specific heat1.0000 kJ/(kg·K)
Lining conductivity1.1000 W/(m·K)
Hot face temperature1,000.0 °C
Cold face temperature100.00 °C
Initial (ambient) temperature30.000 °C

Applying the formula below gives:

ResultValue
Heat stored in the wall19,136 MJ
Steady conduction loss344.35 kW
Storage equal to hours of steady loss15.437 h
Lining mass36.800 t

Open this example in the calculator and change any input.

Formula

\(Q_s = \rho cAL\left(\frac{T_h + T_c}{2} - T_0\right), \quad \dot Q_l = \frac{kA(T_h - T_c)}{L}\)

Variables

Symbol Meaning SI unit
\(A\) Wall area m²
\(L\) Lining thickness m
\(\rho\) Lining density kg/m³
\(c\) Lining specific heat J/(kg·K)
\(k\) Lining conductivity W/(m·K)
\(T_h\) Hot face temperature K
\(T_c\) Cold face temperature K
\(T_0\) Initial (ambient) temperature K
\(Q_s\) Heat stored in the wall J
\(\dot Q_l\) Steady conduction loss W
\(Q_s/\dot Q_l\) Storage equal to hours of steady loss s
\(m\) Lining mass kg

Method and standards

Wall storage.

Where it is used

  • Batch and intermittent furnace design.
  • Lining replacement studies.

Common mistakes

  • Comparing linings only by steady loss.
  • Ignoring storage when estimating cycle fuel.

Assumptions and limits

  • Single uniform layer at steady state.

References

  • Stored and conducted heat of a furnace wall

Questions and answers

Why does lining choice matter for batch furnaces?

Every cycle the lining must be reheated; heavy brick may store more heat than the load receives.

Why use the mean of hot and cold faces?

At steady state the temperature falls linearly through a uniform wall, so the mean equals the average of the faces.

What do the defaults represent?

An illustrative 80 m² of 230 mm firebrick (2,000 kg/m³) at 1,000 °C hot face and 100 °C cold face.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.