Hot gas outflow through an open furnace door above the neutral plane driven by the buoyancy of the furnace atmosphere, and the heat carried out.

Process steam and utilitiesRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Illustrative 1.5 m door, 1200 CSmall peep door 0.3 mWide charging door 3 m, 900 C

Accepted: 0.1 to 10 m
Accepted: 0.02 to 5 m
Accepted: 326.85 to 1,726.8 °C
Accepted: -23.15 to 56.85 °C
Accepted: 0.4 to 1
Accepted: 1 to 1.5 kJ/(kg·K)

Results

Above the neutral plane the furnace is at higher pressure than outside by gz(ρ_a − ρ_g); integrating the outflow velocity over the opening gives ṁ = C_dWρ_g(2/3)√(2g(ρ_a − ρ_g)/ρ_g)h^(3/2) (densities ≈ 353/T). Below the neutral plane cold air flows in. Keep furnace pressure near zero at the hearth and openings short and narrow.

Pressure difference at the top1.8437Pa
Outflow velocity at the top4.0538m/s
Hot gas escaping78.593kg/h
Heat lost with the gas34.657kW

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 1.5 m door, 1200 C. The inputs, in the units selected above:

InputValue
Opening width1.5000 m
Opening height above the neutral plane0.60000 m
Furnace gas temperature1,200.0 °C
Ambient temperature30.000 °C
Discharge coefficient0.60000 -
Gas specific heat1.2500 kJ/(kg·K)

Applying the formula below gives:

ResultValue
Pressure difference at the top5.4416 Pa
Outflow velocity at the top6.7393 m/s
Hot gas escaping2,092.9 kg/h
Heat lost with the gas850.24 kW

Open this example in the calculator and change any input.

Formula

\(\Delta p(z) = gz(\rho_a - \rho_g), \quad \dot m = C_dW\rho_g\frac23\sqrt{\frac{2g(\rho_a - \rho_g)}{\rho_g}}h^{3/2}\)

Variables

Symbol Meaning SI unit
\(W\) Opening width m
\(h\) Opening height above the neutral plane m
\(T_g\) Furnace gas temperature K
\(T_a\) Ambient temperature K
\(C_d\) Discharge coefficient -
\(c_p\) Gas specific heat J/(kg·K)
\(\Delta p_{top}\) Pressure difference at the top Pa
\(v_{top}\) Outflow velocity at the top m/s
\(\dot m_g\) Hot gas escaping kg/s
\(\dot Q\) Heat lost with the gas W

Method and standards

Door losses.

Where it is used

  • Reheating and forging furnace practice.
  • Justifying door seals and pressure control.

Common mistakes

  • Taking the whole door height as above the neutral plane.
  • Ignoring radiation through the opening (a separate loss).

Assumptions and limits

  • Ideal-gas densities 353/T; quiescent surroundings.

References

  • Buoyancy-driven flow through an opening

Questions and answers

What is the neutral plane?

The height where furnace and outside pressures are equal; above it hot gas flows out, below it cold air leaks in.

How is the neutral plane controlled?

By furnace pressure control, normally set slightly positive at the hearth so that cold air does not enter.

What do the defaults represent?

An illustrative 1.5 m wide opening reaching 0.6 m above the neutral plane, furnace at 1,200 °C, 30 °C ambient.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.