Worked example
Example: Illustrative 1.5 m door, 1200 C. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Opening width | 1.5000 m |
| Opening height above the neutral plane | 0.60000 m |
| Furnace gas temperature | 1,200.0 °C |
| Ambient temperature | 30.000 °C |
| Discharge coefficient | 0.60000 - |
| Gas specific heat | 1.2500 kJ/(kg·K) |
Applying the formula below gives:
| Result | Value |
|---|---|
| Pressure difference at the top | 5.4416 Pa |
| Outflow velocity at the top | 6.7393 m/s |
| Hot gas escaping | 2,092.9 kg/h |
| Heat lost with the gas | 850.24 kW |
Open this example in the calculator and change any input.
Formula
\(\Delta p(z) = gz(\rho_a - \rho_g), \quad \dot m = C_dW\rho_g\frac23\sqrt{\frac{2g(\rho_a - \rho_g)}{\rho_g}}h^{3/2}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(W\) | Opening width | m |
| \(h\) | Opening height above the neutral plane | m |
| \(T_g\) | Furnace gas temperature | K |
| \(T_a\) | Ambient temperature | K |
| \(C_d\) | Discharge coefficient | - |
| \(c_p\) | Gas specific heat | J/(kg·K) |
| \(\Delta p_{top}\) | Pressure difference at the top | Pa |
| \(v_{top}\) | Outflow velocity at the top | m/s |
| \(\dot m_g\) | Hot gas escaping | kg/s |
| \(\dot Q\) | Heat lost with the gas | W |
Method and standards
Door losses.
Where it is used
- Reheating and forging furnace practice.
- Justifying door seals and pressure control.
Common mistakes
- Taking the whole door height as above the neutral plane.
- Ignoring radiation through the opening (a separate loss).
Assumptions and limits
- Ideal-gas densities 353/T; quiescent surroundings.
References
- Buoyancy-driven flow through an opening
Questions and answers
What is the neutral plane?
The height where furnace and outside pressures are equal; above it hot gas flows out, below it cold air leaks in.
How is the neutral plane controlled?
By furnace pressure control, normally set slightly positive at the hearth so that cold air does not enter.
What do the defaults represent?
An illustrative 1.5 m wide opening reaching 0.6 m above the neutral plane, furnace at 1,200 °C, 30 °C ambient.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Trinks, Mawhinney, Shannon, Reed and Garvey, Industrial Furnaces, 6th ed. (Wiley, 2004)