FireCADCalc

Continuous Casting: Metallurgical Length and Throughput

Time for a strand to solidify through by the square-root law of shell growth, the metallurgical length at a casting speed, and the caster throughput.

Inputs

Examples: Illustrative 220 mm slab at 1.2 m/minBillet 150 mm at 3 m/min, 6 strandsThin slab 60 mm at 5 m/min

Accepted: 30 to 500 mm
Accepted: 50 to 3,000 mm
Accepted: 0.12 to 9 m/min
Accepted: 15 to 40
Accepted: 1 to 8
Accepted: 7,000 to 8,000 kg/m³

Results

Shell thickness s = K√t (K in mm/min^½, about 25–30 for slabs and billets): the strand is solid when s reaches half the thickness, t_s = (d/2K)². The metallurgical length v_c·t_s must lie inside the machine's supported length; casting faster pushes the liquid core further, limited by bulging and soft-reduction position.

Solidification time7.1747min
Metallurgical length21.524m
Caster throughput184.68t/h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 220 mm slab at 1.2 m/min. The inputs, in the units selected above:

InputValue
Section thickness220.00 mm
Section width1,500.0 mm
Casting speed1.2000 m/min
Solidification constant (mm/min^½)27.000 -
Number of strands2.0000 -
Steel density (solid)7,600.0 kg/m³

Applying the formula below gives:

ResultValue
Solidification time16.598 min
Metallurgical length19.918 m
Caster throughput361.15 t/h

Open this example in the calculator and change any input.

Formula

\(s = K\sqrt t, \quad t_s = \left(\frac{d}{2K}\right)^2, \quad L_m = v_ct_s, \quad \dot m = n_s\rho wdv_c\)

Variables

Symbol Meaning SI unit
\(d\) Section thickness m
\(w\) Section width m
\(v_c\) Casting speed m/s
\(K\) Solidification constant (mm/min^½) -
\(n_s\) Number of strands -
\(\rho\) Steel density (solid) kg/m³
\(t_s\) Solidification time s
\(L_m\) Metallurgical length m
\(\dot m\) Caster throughput kg/s

Method and standards

Casting.

Where it is used

  • Caster speed and machine length checks.
  • Throughput planning.

Common mistakes

  • Using full thickness instead of half.
  • Mixing K units (mm/min½ versus m/s½).

Assumptions and limits

  • One-dimensional shell growth from both faces; constant K.

References

  • Square-root law of shell growth

Questions and answers

Why does the metallurgical length matter?

The strand must be fully solid before the end of the supported zone and before cutting, or it can bulge or break out.

Where does K come from?

From breakout shells or models for the steel grade and cooling intensity; about 25–30 mm/min^½ is typical.

What do the defaults represent?

An illustrative 220 × 1,500 mm slab caster at 1.2 m/min, K = 27 mm/min^½, two strands.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

AISE, The Making, Shaping and Treating of Steel, 11th ed. (AISE Steel Foundation, 1998), Ghosh and Chatterjee, Ironmaking and Steelmaking: Theory and Practice (PHI, 2008)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.