Hydrogen Bake-Out Time for Steel Plate

Time to remove a fraction of dissolved hydrogen from a steel plate baked at temperature, from the slab desorption series with an Arrhenius effective diffusivity.

Inputs

Examples: Illustrative 25 mm plate at 200 C, 90 % out10 mm plate at 250 C, 95 % outPlated 3 mm part at 190 C

Accepted: 0.1 to 500 mm
Accepted: 0.0001 to 10 mm²/s
Accepted: 1 to 100 kJ/mol
Accepted: 0 to 626.85 °C
Accepted: 0.1 to 90 %

Results

Mean concentration in a slab of thickness L degassing from both faces: C̄/C₀ = Σ 8/((2m+1)²π²)·exp(−(2m+1)²π²Dt/L²). Trapping makes the effective diffusivity in steels far lower than lattice values; take D₀ and Q for the steel and microstructure (the defaults are illustrative).

Effective diffusivity9.3320e-04mm²/s
Bake-out time0.37985h
Characteristic time2.6789h

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative 25 mm plate at 200 C, 90 % out. The inputs, in the units selected above:

InputValue
Plate thickness (outgassing from both faces)25.000 mm
Diffusivity pre-exponential (effective)0.10000 mm²/s
Activation energy (effective)18.000 kJ/mol
Bake-out temperature200.00 °C
Fraction of hydrogen to leave in10.000 %

Applying the formula below gives:

ResultValue
Effective diffusivity0.001030 mm²/s
Bake-out time35.734 h
Characteristic time168.54 h

Open this example in the calculator and change any input.

Formula

\(\frac{\bar C}{C_0} = \sum_{m=0}^\infty\frac{8}{(2m+1)^2\pi^2}\exp\left[-\frac{(2m+1)^2\pi^2Dt}{L^2}\right]\)

Variables

Symbol Meaning SI unit
\(L\) Plate thickness (outgassing from both faces) m
\(D_0\) Diffusivity pre-exponential (effective) m²/s
\(Q\) Activation energy (effective) J/mol
\(T\) Bake-out temperature K
\(f\) Fraction of hydrogen to leave in -
\(D\) Effective diffusivity m²/s
\(t\) Bake-out time s
\(L^2/D\) Characteristic time s

Method and standards

Slab desorption.

Where it is used

  • Post-weld and post-plating baking.
  • Hydrogen-induced cracking prevention.

Common mistakes

  • Using lattice diffusivity for trapped hydrogen.
  • Measuring from the plate centre instead of the thickness.

Assumptions and limits

  • Plane sheet; zero surface concentration; constant D.

References

  • Desorption from a plane sheet

Questions and answers

Why does thickness matter so much?

Bake-out time grows with the square of thickness: twice as thick needs four times as long.

Why bake soon after welding or plating?

Hydrogen causes delayed cracking within hours to days; baking before it has time to concentrate at defects prevents it.

What do the defaults represent?

An illustrative 25 mm plate baked at 200 °C with effective D₀ 10⁻⁷ m²/s and Q 18 kJ/mol, removing 90 % of the hydrogen.

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Crank, The Mathematics of Diffusion, 2nd ed. (Oxford, 1975), ch. 4

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.