FireCADCalc

Pitting Factor and Extreme Pit Depth Extrapolation

Pitting factor from the deepest pit and average penetration, and the deepest pit expected over a larger structure area by Gumbel extreme-value scaling.

Thermal power plantProcess steam and utilitiesSugar mill and cogenerationRefinery and petrochemicalChemical and fertiliserPulp and paper

Inputs

Examples: 0.01 m² coupon to 100 m², 6 mm wallTank floor: 1 m² strips to 500 m², 8 mm

Results

Gumbel scale α is fitted from the deepest pits of several equal sample areas (ASTM G46 approach). Extrapolating far beyond the sampled area adds uncertainty. The deepest pit of one sample stands in for the fitted location parameter, and no confidence level is applied.

Pitting factor6.0000
Expected deepest pit over A5.4858mm
Remaining wall at the deepest pit2.5142mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: 0.01 m² coupon to 100 m², 6 mm wall. The inputs, in the units selected above:

InputValue
Deepest pit in the inspected sample0.80000 mm
Average penetration (from weight loss)0.10000 mm
Gumbel scale parameter of pit depths0.12000 mm
Inspected sample area0.010000 m²
Total structure area100.00 m²
Wall thickness6.0000 mm

Applying the formula below gives:

ResultValue
Pitting factor8.0000
Expected deepest pit over A1.9052 mm
Remaining wall at the deepest pit4.0948 mm

Open this example in the calculator and change any input.

Formula

\(PF = \frac{p_{max}}{\bar d}, \quad d_A = p_{max} + \alpha\ln\frac{A}{a}\)

Variables

Symbol Meaning SI unit
\(p_{max}\) Deepest pit in the inspected sample m
\(\bar d\) Average penetration (from weight loss) m
\(\alpha\) Gumbel scale parameter of pit depths m
\(a\) Inspected sample area m²
\(A\) Total structure area m²
\(t\) Wall thickness m
\(PF\) Pitting factor -
\(d_A\) Expected deepest pit over A m
\(t - d_A\) Remaining wall at the deepest pit m

Method and standards

Extreme-value statistics.

Where it is used

  • Tank floors and pipe inspection.
  • Cooling-water exchanger tubes.

Common mistakes

  • Using too few sample areas to fit α.
  • Treating average loss as the life-limiting value.

Assumptions and limits

  • Gumbel distribution of maximum pit depths.
  • The deepest pit of one sample stands in for the Gumbel location parameter λ; the standard procedure fits λ and α from the deepest pits of several samples. The result is a best estimate with no confidence level: add a margin, or use the fitted λ, for an inspection decision.

References

  • Pitting factor (ASTM G46) and Gumbel extreme-value area scaling d_A = d_a + α ln(A/a) (Shibata; Jones, Principles and Prevention of Corrosion, 2nd ed. (Prentice Hall, 1996))

Questions and answers

What does the pitting factor show?

How much deeper the worst pit is than the average loss: 1 means uniform corrosion, large numbers mean localised attack.

Why extrapolate to the whole area?

The larger the area, the deeper the worst pit is likely to be; samples underestimate the structure's worst pit.

What do the defaults represent?

Pits found on a 0.01 m² coupon extrapolated to 100 m² of 6 mm wall.

Method and article reviewed by FireCAD engineering on 13 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.