FireCADCalc

Corrosion Rate from Current Density (Faraday)

Uniform corrosion rate in mm per year and mass loss from a corrosion current density by Faraday's law, from the metal's molar mass, valence and density.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Iron at 0.1 A/m2Copper at 0.02 A/m2Aluminium at 0.05 A/m2

Results

Corrosion rate0.054476mm/a
Mass loss rate0.40269g/(m²·d)

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Iron at 0.1 A/m2. The inputs, in the units selected above:

InputValue
Corrosion current density0.10000 A/m²
Molar mass of the metal55.845 kg/kmol
Electrons per atom (valence)2.0000 -
Metal density7,870.0 kg/m³

Applying the formula below gives:

ResultValue
Corrosion rate0.11604 mm/a
Mass loss rate2.5004 g/(m²·d)

Open this example in the calculator and change any input.

Formula

\(\dot m'' = \frac{i M}{n F}, \quad CR = \frac{\dot m''}{\rho}\)

Variables

Symbol Meaning SI unit
\(i_{corr}\) Corrosion current density A/m²
\(M\) Molar mass of the metal kg/kmol
\(n\) Electrons per atom (valence) -
\(\rho\) Metal density kg/m³
\(CR\) Corrosion rate m/s
\(\dot m''\) Mass loss rate kg/(m²·s)

Method and standards

Faraday's law.

Where it is used

  • Interpreting corrosion probes and LPR readings.
  • CP and coupon studies.

Common mistakes

  • µA/cm² vs A/m² (1 µA/cm² = 0.01 A/m²).
  • Wrong valence.

Assumptions and limits

  • Uniform corrosion.

References

  • Faraday's law: mass loss = i M/(n F); penetration = mass loss/ρ (as in ASTM G102)

Questions and answers

Iron at 10 µA/cm² (0.1 A/m²)?

About 0.116 mm/a.

Where does i_corr come from?

Polarisation resistance or Tafel measurements.

Pitting?

Local rates are many times the average.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.