Electroplating Thickness and Time (Faraday)

Plated thickness from current, time, area and current efficiency by Faraday's law, and the time for a target thickness, for any metal entered by its data.

Thermal power plantRefinery and petrochemicalChemical and fertiliser

Inputs

Examples: Nickel 50 A, 30 minZinc 120 A, 20 min

Results

Average thickness; edges plate thicker and recesses thinner.

Mass deposited41.470g
Thickness1.4520µm
Current density0.30000A/dm²
Time for the target thickness110.19min

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Nickel 50 A, 30 min. The inputs, in the units selected above:

InputValue
Plating current50.000 A
Plating time30.000 min
Area being plated1.5000 m²
Cathode current efficiency90.000 %
Molar mass of the deposited metal58.693 kg/kmol
Electrons per ion2.0000 -
Deposit density8,908.0 kg/m³
Target thickness10.000 µm

Applying the formula below gives:

ResultValue
Mass deposited24.637 g
Thickness1.8438 µm
Current density0.33333 A/dm²
Time for the target thickness162.71 min

Open this example in the calculator and change any input.

Formula

\(m = \frac{I t \eta M}{n F}, \quad \delta = \frac{m}{\rho A}\)

Variables

Symbol Meaning SI unit
\(I\) Plating current A
\(t\) Plating time s
\(A\) Area being plated m²
\(\eta\) Cathode current efficiency -
\(M\) Molar mass of the deposited metal kg/kmol
\(n\) Electrons per ion -
\(\rho\) Deposit density kg/m³
\(\delta_t\) Target thickness m
\(m\) Mass deposited kg
\(\delta\) Thickness m
\(i\) Current density A/m²
\(t_t\) Time for the target thickness s

Method and standards

Faraday's law.

Where it is used

  • Plating shops and repair of shafts.
  • Estimating plating cost.

Common mistakes

  • Ignoring efficiency.
  • Area of one side only.

Assumptions and limits

  • Uniform deposit.
  • The metal is defined by its molar mass, electrons per ion and deposit density, entered by you; the defaults are nickel.
  • With zero current the time to the target is not shown.

References

  • Faraday's law m = I t η M/(n F); thickness = m/(ρA)

Questions and answers

50 A on 1.5 m² of nickel for 30 min at 90 %?

About 1.8 µm.

Chrome?

Hexavalent chrome baths have low efficiency (10–25 %), so they plate slowly.

Current density?

Keep within the bath supplier's range to avoid burning.

Method and article reviewed by FireCAD engineering on 12 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.