FireCADCalc

Shaft Alignment: Thermal Growth and Cold Offset

Vertical thermal growth of a driver and driven machine from their foot-to-shaft heights and temperature rises, and the cold offset to set at alignment.

Inputs

Examples: Illustrative motor and hot-water pumpSteam turbine and generatorCold pump (shrinks)

Accepted: 10 to 5,000 mm
Accepted: 1 to 30 µm/(m·K)
Accepted: -50 to 400 K
Accepted: 10 to 5,000 mm
Accepted: 1 to 30 µm/(m·K)
Accepted: -50 to 400 K

Results

Each machine's shaft rises by α h ΔT as its casing warms between the feet and the centreline. If the driven machine (a hot pump or turbine) grows more than the motor, set the motor higher by the difference when cold, so the shafts come into line at running temperature. Use the mean temperature rise of the supports, not of the process fluid; pedestal heating, piping forces and soft feet also move machines, so confirm with hot-alignment checks where it matters.

Driver growth0.055000mm
Driven growth-0.066000mm
Set the driver this much higher when cold (negative = lower)-0.12100mm

Download PDF CSV Link to this result Compare another case

Log in to save calculations to your dashboard.

Worked example

Example: Illustrative motor and hot-water pump. The inputs, in the units selected above:

InputValue
Driver: foot to shaft centreline height355.00 mm
Driver casing expansion coefficient11.000 µm/(m·K)
Driver casing mean temperature rise25.000 K
Driven: foot to shaft centreline height300.00 mm
Driven casing expansion coefficient11.000 µm/(m·K)
Driven casing mean temperature rise120.00 K

Applying the formula below gives:

ResultValue
Driver growth0.097625 mm
Driven growth0.39600 mm
Set the driver this much higher when cold (negative = lower)0.29837 mm

Open this example in the calculator and change any input.

Formula

\(\delta = \alpha h \Delta T, \quad \text{cold offset} = \delta_2 - \delta_1\)

Variables

Symbol Meaning SI unit
\(h_1\) Driver: foot to shaft centreline height m
\(\alpha_1\) Driver casing expansion coefficient 1/K
\(\Delta T_1\) Driver casing mean temperature rise K
\(h_2\) Driven: foot to shaft centreline height m
\(\alpha_2\) Driven casing expansion coefficient 1/K
\(\Delta T_2\) Driven casing mean temperature rise K
\(\delta_1\) Driver growth m
\(\delta_2\) Driven growth m
\(\delta_2 - \delta_1\) Set the driver this much higher when cold (negative = lower) m

Method and standards

Thermal growth.

Where it is used

  • Aligning hot pumps, turbines and compressors.
  • Explaining vibration that appears only when hot.

Common mistakes

  • Using the process temperature as the casing temperature.
  • Applying the offset to the wrong machine.

Assumptions and limits

  • Uniform casing temperature rise; vertical growth only.

References

  • Linear thermal expansion of machine supports

Questions and answers

How much does a hot pump grow?

About 0.4 mm for 300 mm of steel heated by 120 K.

Which machine should be set high?

The one that grows less when hot, by the difference in growth.

What do the defaults represent?

An illustrative motor (355 mm shaft height, 25 K rise) driving a hot-water pump (300 mm, 120 K rise).

Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.

Sources

Piotrowski, Shaft Alignment Handbook, 3rd ed. (CRC Press, 2006)

Related calculators

Free engineering calculators: every page computes in SI and converts to your units. Results are for engineering estimation; verify critical designs against the referenced standards.

Rejoining the server...

Rejoin failed... trying again in seconds.

Failed to rejoin.
Please retry or reload the page.

The session has been paused by the server.

Failed to resume the session.
Please retry or reload the page.