Worked example
Example: Illustrative motor and hot-water pump. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Driver: foot to shaft centreline height | 355.00 mm |
| Driver casing expansion coefficient | 11.000 µm/(m·K) |
| Driver casing mean temperature rise | 25.000 K |
| Driven: foot to shaft centreline height | 300.00 mm |
| Driven casing expansion coefficient | 11.000 µm/(m·K) |
| Driven casing mean temperature rise | 120.00 K |
Applying the formula below gives:
| Result | Value |
|---|---|
| Driver growth | 0.097625 mm |
| Driven growth | 0.39600 mm |
| Set the driver this much higher when cold (negative = lower) | 0.29837 mm |
Open this example in the calculator and change any input.
Formula
\(\delta = \alpha h \Delta T, \quad \text{cold offset} = \delta_2 - \delta_1\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(h_1\) | Driver: foot to shaft centreline height | m |
| \(\alpha_1\) | Driver casing expansion coefficient | 1/K |
| \(\Delta T_1\) | Driver casing mean temperature rise | K |
| \(h_2\) | Driven: foot to shaft centreline height | m |
| \(\alpha_2\) | Driven casing expansion coefficient | 1/K |
| \(\Delta T_2\) | Driven casing mean temperature rise | K |
| \(\delta_1\) | Driver growth | m |
| \(\delta_2\) | Driven growth | m |
| \(\delta_2 - \delta_1\) | Set the driver this much higher when cold (negative = lower) | m |
Method and standards
Thermal growth.
Where it is used
- Aligning hot pumps, turbines and compressors.
- Explaining vibration that appears only when hot.
Common mistakes
- Using the process temperature as the casing temperature.
- Applying the offset to the wrong machine.
Assumptions and limits
- Uniform casing temperature rise; vertical growth only.
References
- Linear thermal expansion of machine supports
Questions and answers
How much does a hot pump grow?
About 0.4 mm for 300 mm of steel heated by 120 K.
Which machine should be set high?
The one that grows less when hot, by the difference in growth.
What do the defaults represent?
An illustrative motor (355 mm shaft height, 25 K rise) driving a hot-water pump (300 mm, 120 K rise).
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Piotrowski, Shaft Alignment Handbook, 3rd ed. (CRC Press, 2006)