Worked example
Example: Illustrative probe at -10 V. The inputs, in the units selected above:
| Input | Value |
|---|---|
| DC gap voltage (magnitude) | 10.000 V |
| Probe sensitivity (V per mm) | 7.8700 - |
| AC signal peak to peak | 0.40000 V |
| Shaft speed | 3,000.0 rpm |
| End of linear range (gap) | 2.2900 mm |
| Start of linear range (gap) | 0.25000 mm |
Applying the formula below gives:
| Result | Value |
|---|---|
| Probe gap | 1.2706 mm |
| Shaft displacement peak to peak | 50.826 µm |
| Running-speed frequency | 50.000 Hz |
| Margin to the linear range limit | 1.0194 mm |
| Vibration within range (1 = yes) | 1.0000 |
Open this example in the calculator and change any input.
Formula
\(g = \frac{|V_{gap}|}{S}, \quad x_{pp} = \frac{V_{pp}}{S}, \quad f = \frac{n}{60}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(V_{gap}\) | DC gap voltage (magnitude) | V |
| \(S\) | Probe sensitivity (V per mm) | - |
| \(V_{pp}\) | AC signal peak to peak | V |
| \(n\) | Shaft speed | rad/s |
| \(g_{max}\) | End of linear range (gap) | m |
| \(g_{min}\) | Start of linear range (gap) | m |
| \(g\) | Probe gap | m |
| \(x_{pp}\) | Shaft displacement peak to peak | m |
| \(f_{1\times}\) | Running-speed frequency | 1/s |
| \(\min(g - g_{min}, g_{max} - g)\) | Margin to the linear range limit | m |
| \(x_{pp}/2 \le margin\) | Vibration within range (1 = yes) | - |
Method and standards
Proximity probe.
Where it is used
- Turbine and compressor vibration monitoring.
- Gap setting during installation.
Common mistakes
- Using mils and millimetres together.
- Setting the gap near the end of the linear range.
Assumptions and limits
- Linear probe response; calibrated target material.
References
- Eddy-current displacement probe scaling
Questions and answers
Why set the gap at about −10 V?
It is near the middle of the linear range, leaving room for vibration and thermal or bearing movement.
Does shaft material matter?
Yes: sensitivity is calibrated for a particular steel; other materials change the scale factor.
What do the defaults represent?
An illustrative 8 mm probe system at 7.87 V/mm reading −10.0 V gap and 0.40 V peak to peak at 3,000 rpm.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.