Worked example
Example: Illustrative 50/200 mm chamber at 250 Hz. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Inlet and outlet pipe diameter | 50.000 mm |
| Chamber diameter | 200.00 mm |
| Chamber length | 300.00 mm |
| Frequency | 250.00 Hz |
| Gas temperature | 20.000 °C |
Applying the formula below gives:
| Result | Value |
|---|---|
| Area ratio | 16.000 |
| Speed of sound | 343.23 m/s |
| Transmission loss at the frequency (dB) | 17.927 |
| Peak transmission loss (dB) | 18.096 |
| First pass frequency (zero loss) | 572.05 Hz |
| First frequency of peak loss | 286.03 Hz |
Open this example in the calculator and change any input.
Formula
\(TL = 10\log_{10}\left[1 + \frac14\left(m - \frac1m\right)^2\sin^2 kL\right], \quad m = \left(\frac{d_2}{d_1}\right)^2, \quad k = \frac{2\pi f}{c}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(d_1\) | Inlet and outlet pipe diameter | m |
| \(d_2\) | Chamber diameter | m |
| \(L\) | Chamber length | m |
| \(f\) | Frequency | 1/s |
| \(T\) | Gas temperature | K |
| \(m\) | Area ratio | - |
| \(c\) | Speed of sound | m/s |
| \(TL\) | Transmission loss at the frequency (dB) | - |
| \(TL_{max}\) | Peak transmission loss (dB) | - |
| \(f_p\) | First pass frequency (zero loss) | 1/s |
| \(f_{pk}\) | First frequency of peak loss | 1/s |
Method and standards
Expansion chamber.
Where it is used
- Engine, blower and compressor silencers.
- Vent and intake silencers.
Common mistakes
- Using the formula above the first cross mode.
- Tuning the chamber to the wrong engine firing frequency.
Assumptions and limits
- Plane waves; no flow or absorption; rigid walls.
References
- Plane-wave transmission loss of a simple expansion chamber
Questions and answers
How much can a simple chamber attenuate?
Up to 10 log₁₀[1 + ¼(m − 1/m)²]: about 18 dB for an area ratio of 16.
Why does it pass some frequencies?
When the chamber is a whole number of half wavelengths long it becomes acoustically transparent.
What do the defaults represent?
An illustrative 50 mm pipe into a 200 mm chamber 300 mm long, air at 20 °C, at 250 Hz.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Munjal, Acoustics of Ducts and Mufflers, 2nd ed. (Wiley, 2014)