Worked example
Example: Illustrative field readings, 20 g trials. The inputs, in the units selected above:
| Input | Value |
|---|---|
| Original vibration at bearing A (amplitude) | 8.0000 - |
| Its phase | 35.000 ° |
| Original vibration at bearing B | 6.0000 - |
| Its phase | 120.00 ° |
| Trial mass in plane 1 | 20.000 g |
| Trial mass angle in plane 1 | 0 ° |
| Vibration at A with trial 1 | 5.5000 - |
| Its phase | 85.000 ° |
| Vibration at B with trial 1 | 5.2000 - |
| Its phase | 140.00 ° |
| Trial mass in plane 2 (trial 1 removed) | 20.000 g |
| Trial mass angle in plane 2 | 0 ° |
| Vibration at A with trial 2 | 7.0000 - |
| Its phase | 50.000 ° |
| Vibration at B with trial 2 | 3.0000 - |
| Its phase | 160.00 ° |
Applying the formula below gives:
| Result | Value |
|---|---|
| Correction mass in plane 1 | 20.167 g |
| Correction angle in plane 1 | 51.251 ° |
| Correction mass in plane 2 | 18.717 g |
| Correction angle in plane 2 | 31.137 ° |
Open this example in the calculator and change any input.
Formula
\(\begin{bmatrix}\alpha_{A1} & \alpha_{A2}\\ \alpha_{B1} & \alpha_{B2}\end{bmatrix}\begin{bmatrix}M_1\\ M_2\end{bmatrix} = -\begin{bmatrix}A_0\\ B_0\end{bmatrix}, \quad \alpha_{A1} = \frac{A_1 - A_0}{W_1}\)
Variables
| Symbol | Meaning | SI unit |
|---|---|---|
| \(A_0\) | Original vibration at bearing A (amplitude) | - |
| \(\phi_{A0}\) | Its phase | rad |
| \(B_0\) | Original vibration at bearing B | - |
| \(\phi_{B0}\) | Its phase | rad |
| \(W_1\) | Trial mass in plane 1 | kg |
| \(\theta_1\) | Trial mass angle in plane 1 | rad |
| \(A_1\) | Vibration at A with trial 1 | - |
| \(\phi_{A1}\) | Its phase | rad |
| \(B_1\) | Vibration at B with trial 1 | - |
| \(\phi_{B1}\) | Its phase | rad |
| \(W_2\) | Trial mass in plane 2 (trial 1 removed) | kg |
| \(\theta_2\) | Trial mass angle in plane 2 | rad |
| \(A_2\) | Vibration at A with trial 2 | - |
| \(\phi_{A2}\) | Its phase | rad |
| \(B_2\) | Vibration at B with trial 2 | - |
| \(\phi_{B2}\) | Its phase | rad |
| \(M_1\) | Correction mass in plane 1 | kg |
| \(\theta_{c1}\) | Correction angle in plane 1 | rad |
| \(M_2\) | Correction mass in plane 2 | kg |
| \(\theta_{c2}\) | Correction angle in plane 2 | rad |
Method and standards
Two-plane balancing.
Where it is used
- Field balancing of fans, rolls and motors.
- Balancing long rotors in place.
Common mistakes
- Mixing phase conventions between readings and trial masses.
- Leaving trial 1 on during trial 2.
Assumptions and limits
- Linear system; constant speed; rigid rotor in the balancing range.
References
- Influence-coefficient method for two-plane field balancing
Questions and answers
When is two-plane balancing needed?
When the rotor is long compared with its diameter, or when the unbalance shows as a rocking (couple) motion between bearings.
Why remove trial 1 before trial 2?
Each trial must be measured alone so that its influence on both bearings is known.
What do the defaults represent?
Illustrative field readings in µm or mm/s with 20 g trial masses at 0° in each plane.
Method and article reviewed by FireCAD engineering on 17 November 2026. Every result is checked against an independent calculation on each release: how we verify our calculators.
Sources
Wowk, Machinery Vibration: Balancing (McGraw-Hill, 1995)